Analytical simulation of reversed cyclic lateral behaviors of an RC shear wall sub-assemblage
- Authors
- Lee, Han Seon; Jeong, Da Hun; Hwang, Kyung Ran
- Issue Date
- 8월-2012
- Publisher
- TECHNO-PRESS
- Keywords
- reinforced concrete; nonlinear analysis; PERFORM-3D; wall sub-assemblage
- Citation
- COMPUTERS AND CONCRETE, v.10, no.2, pp.173 - 196
- Indexed
- SCIE
SCOPUS
KCI
OTHER
- Journal Title
- COMPUTERS AND CONCRETE
- Volume
- 10
- Number
- 2
- Start Page
- 173
- End Page
- 196
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/107842
- ISSN
- 1598-8198
- Abstract
- Experimental results of cyclic reversed lateral force test on a two-story reinforced concrete shear wall sub-assemblage are simulated analytically by using the PERFORM-3D program. A comparison of experimental and analytical results leads to the following conclusions: (1) "Shear Wall" and "General Wall" models with "Concrete shear" cannot simulate the pinching phenomena due to shear and show larger amounts of inelastic energy absorption than those in the experiment. (2) Modeling a story-height wall by using two or more "General Wall" elements with "Diagonal shear" in the vertical direction induces the phenomenon of swelling-out at the belly, leading to the erroneous simulation of shear behaviors. In application to tall building structures, it is recommended to use one element of "General Wall" with "Diagonal shear" for the full height of a story. (3) In the plastic hinge area, concrete deformations of analytical models overestimate elongation and underestimate shortening when compared with experimental results.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.