Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Correlation of Fundus Autofluorescence Gray Values with Vision and Microperimetry in Resolved Central Serous Chorioretinopathy

Authors
Oh, JaeryungKim, Seong-WooKwon, Soon-SunOh, In KyungHuh, Kuhl
Issue Date
Jan-2012
Publisher
ASSOC RESEARCH VISION OPHTHALMOLOGY INC
Citation
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, v.53, no.1, pp.179 - 184
Indexed
SCIE
SCOPUS
Journal Title
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
Volume
53
Number
1
Start Page
179
End Page
184
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/109170
DOI
10.1167/iovs.11-8704
ISSN
0146-0404
Abstract
PURPOSE. To evaluate the prognostic value of grayscale parameters in fundus autofluorescence (FAF) for visual function in resolved central serous chorioretinopathy (CSC). METHODS. Seventy-six eyes of 67 patients with CSC that had been resolved for more than 4 months were analyzed retrospectively. Both the short-wavelength (SW)-FAF and near infrared (NIR)-FAF gray value parameters, including the mean, standard deviation, and coefficient of variation (CV), were calculated at 350-mu m- and 1200-mu m-diameter circles centered on the fovea. The FAF gray value parameters correlated with -logMAR best corrected visual acuity (BCVA) and mean microperimetry (MP) at the 2 degrees and 4 degrees diameters from the foveal center. RESULTS. The mean -logMAR BCVA was 0.15 +/- 0.23. The mean MP was 12.87 +/- 3.79 dB at 2 and 13.54 +/- 3.37 dB at 4 degrees. The +/- logMAR BCVA correlated most strongly with the mean SW-FAF gray value at the 350-mu m circle centered around the fovea (SW-M350; rho = 0.353; P = 0.002), and the SD of the SW-FAF gray value at the 350-mu m circle centered around the fovea (SW-SD350) correlated most strongly with the MP at 2 degrees (rho = -0.416, P < 0.0001) and 4 degrees (rho = -0.435, P < 0.0001). The NIR-FAF gray value parameters did not correlate with the macular function tests. CONCLUSIONS. In subjects with resolved CSC, FAF gray values correlated with visual function. BCVA correlated most strongly with SW-M350. MP at 2 degrees and at 4 degrees correlated most strongly with SW-SD350. (Invest Ophthalmol Vis Sci. 2012; 53:179-184) DOI:10.1167/iovs.11-8704
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Jae Ryung photo

Oh, Jae Ryung
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE