Plastic limit loads for piping branch junctions under out-of-plane bending
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Kuk-Hee | - |
dc.contributor.author | Xu, Yinghu | - |
dc.contributor.author | Jeon, Jun-Young | - |
dc.contributor.author | Kim, Yun-Jae | - |
dc.contributor.author | Budden, Peter J. | - |
dc.date.accessioned | 2021-09-06T23:56:06Z | - |
dc.date.available | 2021-09-06T23:56:06Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 0309-3247 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/109325 | - |
dc.description.abstract | This paper presents approximate closed-form plastic limit load solutions for branch junctions under out-of-plane bending and under combined pressure and out-of-plane bending, based on three-dimensional finite element limit analyses for an elastic-perfectly plastic material. When bending is applied to the branch pipe, the plastic limit loads for out-of-plane bending are shown to be lower than those for in-plane bending. However, for bending to the run pipe, the opposite trend is found. For combined pressure and out-of-plane bending, either the circular interaction or the parabolic interaction rule can be used, depending on the bending location and the branch geometry. Comparison with published experimental plastic limit load data shows that the predictions agree relatively well with the test data. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SAGE PUBLICATIONS LTD | - |
dc.subject | INTERNAL-PRESSURE | - |
dc.title | Plastic limit loads for piping branch junctions under out-of-plane bending | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Yun-Jae | - |
dc.identifier.doi | 10.1177/0309324711427001 | - |
dc.identifier.scopusid | 2-s2.0-84863285744 | - |
dc.identifier.wosid | 000299482600003 | - |
dc.identifier.bibliographicCitation | JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, v.47, no.1, pp.32 - 45 | - |
dc.relation.isPartOf | JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN | - |
dc.citation.title | JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN | - |
dc.citation.volume | 47 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 32 | - |
dc.citation.endPage | 45 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Mechanics | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
dc.relation.journalWebOfScienceCategory | Mechanics | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Characterization & Testing | - |
dc.subject.keywordPlus | INTERNAL-PRESSURE | - |
dc.subject.keywordAuthor | Branch junction | - |
dc.subject.keywordAuthor | combined pressure and out-of-plane bending | - |
dc.subject.keywordAuthor | finite element limit analysis | - |
dc.subject.keywordAuthor | limit load | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.