사무공간 구조에 따른 실내공기 중 생물학적 오염분포 특성
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 원동환 | - |
dc.contributor.author | 허은혜 | - |
dc.contributor.author | 정호철 | - |
dc.contributor.author | 문경환 | - |
dc.date.accessioned | 2021-09-07T01:50:04Z | - |
dc.date.available | 2021-09-07T01:50:04Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 1738-4087 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/109922 | - |
dc.description.abstract | Objectives: This study was undertaken in order to evaluate by work space zoning and structure the concentrations of biological contaminants in the indoor air of domestic office buildings. Methods: Air samples were collected in the office spaces of 15 office buildings in Seoul from June 28 to July 28, 2011. Prior to the sampling, each office was classified into 'open-plan office', 'cellular office' and 'mixed office' according to the work space zoning. To evaluate the biological contamination of indoor air, total suspended bacteria (TSB), Gram positive bacteria (GPB), Staphylococcus aureus (S.A), Methicillin-resistant Staphylococcus aureus (MRSA), Gram negative bacteria (GNB) and fungi were investigated. During the sampling, temperature, relative humidity and carbon dioxide (CO2) were measured. Results: The TSB concentrations (GM±GSD) were 452 (±1.3) cfu/m3 in open-plan offices, 366 (±1.3) cfu/m3in cellular offices and 287 (±1.5) cfu/m3 in mixed offices, and there were significant differences between the three groups (p<0.05). The highest concentrations (GM ± GSD) of fungi were found in the indoor air of cellular offices 128(±1.0) cfu/m3, which was at least three times higher than the concentrations in mixed offices 43 (±1.0)cfu/m3 (p<0.05). Conclusions: Microbiological contamination in the indoor air of office buildings by work space structure was the highest with the open-plan office layout which includes no high walls or doors separating the occupants | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 한국환경보건학회 | - |
dc.title | 사무공간 구조에 따른 실내공기 중 생물학적 오염분포 특성 | - |
dc.title.alternative | Microbiological Contamination in Office Buildings by Work Space Structure | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 문경환 | - |
dc.identifier.bibliographicCitation | 한국환경보건학회지, v.38, no.03, pp.213 - 222 | - |
dc.relation.isPartOf | 한국환경보건학회지 | - |
dc.citation.title | 한국환경보건학회지 | - |
dc.citation.volume | 38 | - |
dc.citation.number | 03 | - |
dc.citation.startPage | 213 | - |
dc.citation.endPage | 222 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001669996 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | open plan offices | - |
dc.subject.keywordAuthor | indoor air quality | - |
dc.subject.keywordAuthor | microbiological contaminants | - |
dc.subject.keywordAuthor | office building | - |
dc.subject.keywordAuthor | work space structure | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.