LED와 CMOS 이미지 센서 기반 간 기능 분석용 소형 광학장치A Compact Optical System using LED and CMOS Image Sensor for Liver Function Analysis

Other Titles
A Compact Optical System using LED and CMOS Image Sensor for Liver Function Analysis
Authors
김철임창진남명현김동식서성규박정호
Issue Date
2012
Publisher
대한전기학회
Keywords
LED; CMOS image sensor; Liver function test; Low cost; AST(Aspartate aminotransferase); ALT (Alanine aminotransferase); Total bilirubin
Citation
전기학회논문지, v.61, no.2, pp.270 - 275
Indexed
SCOPUS
KCI
Journal Title
전기학회논문지
Volume
61
Number
2
Start Page
270
End Page
275
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/110029
ISSN
1975-8359
Abstract
This paper presents a portable and compact optical device which can conveniently be used to perform a functional analysis of human liver function. The proposed system employed red/green LEDs, as a light source, and CMOS image sensor, which is commonly used in cellular phones. With this system, several blood serum samples have been evaluated for liver functional analysis by measuring light absorption level through the blood serum samples depending on aspartate aminotransferase (AST), alanine aminotransferase (ALT), and total bilirubin concentration. The light absorption through the blood serum samples containing AST, ALT, or total bilirubin can provide their concentrations. The green light absorption is more sensitive to the concentration of AST or ALT, and the red light absorption is more sensitive to the total bilirubuin concentration. Additional calibration steps were performed by using a MATLAB program in order to eliminate the light scattering effects from the extraneous particles existing in each blood serum sample. From the blind test, three standard light intensity curves through each enzyme have been obtained and the enzyme concentration values have been compared to those obtained from a commercially available biochemistry analyzer (Toshiba 200 FR). The average percent difference in the obtained concentrations from two systems for AST,ALT, and total bilirubin concentration came out to be 7.79%, 7.98%. and 7.56%, respectively, with the adjusted coefficient of determination (R2) higher than 0.98. This system can possibly lead to a low-cost and simple system that can be used as a point-of-care (POC) system in a condition without advanced equipments.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Electronics and Information Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seo, Sung kyu photo

Seo, Sung kyu
전자·정보공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE