Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

도농복합지역 지하수 함양과 배출에 대한 연구Groundwater Recharge and Discharge in the Urban-rural Composite Area

Other Titles
Groundwater Recharge and Discharge in the Urban-rural Composite Area
Authors
이병선홍성우강희준이지성윤성택남경필
Issue Date
2012
Publisher
한국지하수토양환경학회
Keywords
The urban-rural composite area; Groundwater; Recharge; Discharge
Citation
지하수토양환경, v.17, no.2, pp.37 - 46
Indexed
KCI
Journal Title
지하수토양환경
Volume
17
Number
2
Start Page
37
End Page
46
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/110267
ISSN
1598-6438
Abstract
This study was conducted to identify groundwater recharge and discharge amounts of a representative urban-rural composite area located in Yongin city, Kyounggi-do, Korea. Groundwater recharge would be affected by mainly two processes in the study area: rainfall and leakage from public water pipelines including water-supply and sewage system. Groundwater recharge rate was estimated to be 13.5% by applying annual groundwater level data from two National Groundwater Monitoring Stations to the master regression curve method. Subseguently, the recharge amounts were determined to be 13,253 × 10^3㎥/yr. Leakage amounts from water-supply and sewage system were estimated to be 3,218 × 10^3 and 5,696 × 10^3㎥/yr, respectively. On the whole, a total of the recharge amounts was 22,167 × 10^3㎥/yr, of which 60% covers rainfall recharge and 40% pipeline leakage. Groundwater discharge occurred through three processes in the composite area: baseflow, well pumping, and discharge from urban infrastructure including groundwater infiltration into sewage pipeline and artificial extraction of groundwater to protect underground facilities from submergence. Discharge amounts by baseflow flowing to the Kiheung agricultural reservoir and well pumping were estimated to be 382 × 10^3 and 1,323 × 10^3㎥/yr, respectively. Occurrence of groundwater infiitration into sewage pipeline was rarely identified. Groundwater extraction amounts from the Bundang subway line as an underground facility were identified as 714 × 10^3㎥/yr. Overall, a total of the discharge amounts was determined to be 2,419 × 10^3㎥/yr, which was contributed by 29% of artificial discharge. Even though groundwater budget of the composite area was identified to be a surplus, it should be managed for a sound groundwater environment by changing deteriorated pipelines and controlling artificial discharge amounts.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science > Department of Earth and Environmental Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher YUN, Seong Taek photo

YUN, Seong Taek
College of Science (Department of Earth and Environmental Sciences)
Read more

Altmetrics

Total Views & Downloads

BROWSE