Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Single Molecule Tracking of a Semiflexible Polyelectrolyte Chain in Solvent Under Uniform Electroosmotic Flows

Authors
Choung, SunghunChun, Myung-SukKim, Chongyoup
Issue Date
10월-2011
Publisher
KOREAN PHYSICAL SOC
Keywords
Single molecule tracking; Polyelectrolyte; Chain conformation; Translational diffusion; Uniform flow; Rheology
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.59, no.4, pp.2847 - 2854
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
59
Number
4
Start Page
2847
End Page
2854
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/111496
DOI
10.3938/jkps.59.2847
ISSN
0374-4884
Abstract
Direct single molecule tracking of a polyelectrolyte chain by using fluorescence microscopy has allowed both the assumptions and the predictions of relevant theories to be tested. The center-of-mass displacement is determined as a function of the time that elapses between images, where the radius of gyration can be estimated from a first moment of the image distribution. The translational self-diffusion for the molecule is an ensemble property of the mean square displacement (MSD) with lag time in each trajectory. Experimentally viable two-dimensional imaging of semiflexible polyelectrolyte was performed on a fluorescein-labeled xanthan chain in electroosmosis-driven uniform flow fields. The radius of gyration was almost constant under variations of the electroosmotic flow velocity determined by an externally applied electric field. We try to develop a correction of the MSD in flow field, taking into account the velocity fluctuations. Its advantage allows acquiring the linear fit for the MSD vs lag time, for a good estimate of the translational diffusion. Increasing behavior of the diffusion with increasing fluid velocity ensures a quadratic equation fit, which should connect with the convective effect. Our results exhibit a screening effect such that strong screening caused by a high ionic concentration leads to higher diffusion due to the compact chain conformation. Considering the uniform flow serves as a basis for understanding the behavior of individual polyelectrolyte chains under controlled fluidic flow in confined spaces.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical and Biological Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE