Recovery estimation for over-current test of non-inductive fault current limiters using numerical analysis
- Authors
- Kim, Young Jae; Chang, Ki Sung; Jo, Hyun Chul; Yoon, Yong Soo; Lee, Jong-Hoon; Lee, Haigun; Ko, Tae Kuk
- Issue Date
- 6월-2011
- Publisher
- ELSEVIER SCI LTD
- Keywords
- High T-c superconductors; Heat transfer; Fault current limiter
- Citation
- CRYOGENICS, v.51, no.6, pp.261 - 265
- Indexed
- SCIE
SCOPUS
- Journal Title
- CRYOGENICS
- Volume
- 51
- Number
- 6
- Start Page
- 261
- End Page
- 265
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/112264
- DOI
- 10.1016/j.cryogenics.2010.07.007
- ISSN
- 0011-2275
- Abstract
- When an FITS coated conductor (CC) is used as a conductor of a superconducting fault current limiter (SFCL), the CC is expected to be exposed to the over-current and temperature of the CC is expected to be increased rapidly by electrical joule heating. Because the CC is a composite tape, thermal and electrical properties of composite materials could affects over-current limiting capacity and recovery time of SFCL This paper presents experimental and numerical results of over-current test and recovery time measurement test on four bifilar wound SFCL modules. The temperature transitions of the samples were estimated from total electrical resistance of the coils. We fabricated one bifilar solenoid coil and three bifilar pancake coils whose cryogenic conditions were different from the other coils. An numerical model was also fabricated to simulate the temperature transition and the numerical results were compared with experimental results. (C) 2010 Elsevier Ltd. All rights reserved.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > Department of Materials Science and Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.