Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The change of macular thickness measured by optical coherence tomography in relation to glycemic control in diabetic patients

Authors
Moon, Sang WoongKim, Hee-YoungKim, Seong-WooOh, JaeryungHuh, KuhlOh, In Kyung
Issue Date
6월-2011
Publisher
SPRINGER
Keywords
Diabetic macular edema; Glycosylated hemoglobin; Optical coherence tomography
Citation
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, v.249, no.6, pp.839 - 848
Indexed
SCIE
SCOPUS
Journal Title
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
Volume
249
Number
6
Start Page
839
End Page
848
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/112406
DOI
10.1007/s00417-010-1562-z
ISSN
0721-832X
Abstract
To demonstrate the change in macular thickness using optical coherence tomography in diabetic patients and to assess its relationship with glycosylated hemoglobin (HbA1c) levels. Diabetic patients who underwent at least two macular thickness measurements with OCT within a 12-month period were included. HbA1c values within 1 month of each OCT study, and clinical data such as age, insulin treatment, systemic hypertension, and the severity of diabetic retinopathy were collected. The change in three macula parameters including center point thickness (CPT), central subfoveal macular thickness (CSMT), and total macular volume (TMV) between two measurements was calculated. Patients were divided into two groups based on the half-width of the 95% confidence interval for percent change, the increase group (group 1) and the decrease group (group 2). The associations of CPT change, CSMT change, and TMV change with baseline HbA1c levels, HbA1c change, and other clinical factors were investigated using correlation analysis and group comparison. A total of 23 eyes of 23 patients were studied. In correlation analysis; the increase in CPT, CSMT, and TMV was correlated with baseline HbA1c (CPT, Spearman's rho = 0.462, p = 0.027; CSMT, Spearman's rho = 0.479, p = 0.021; TMV, Spearman's rho = 0.589, p = 0.003), and the change of HbA1c (CPT, Spearman's rho = -0.585, p = 0.003; CSMT, Spearman's rho = -0.583, p = 0.004; TMV, Spearman's rho = -0.725, p < 0.001). In group comparison for CPT, group 1 have a higher baseline HbA1c (11.2% vs 8.7% of THb, p = 0.044) and a greater HbA1c reduction (-3.3% vs -1.2% of THb, p = 0.044) than group 2. For CSMT, group 1 tended to have a greater HbA1c reduction (-2.9% vs -1.2% of THb, p = 0.074) than group 2. For TMV, group 1 had a higher baseline HbA1c (11.6% vs 8.4% of THb, p = 0.001) and a greater HbA1c reduction (-3.5% vs -0.5% of THb, p < 0.001) than group 2. The change in macular thickness and volume developed in relation to HbA1c levels during a less than 12-month period. A high baseline HbA1c and a large reduction of HbA1c were risk factors for the increase in macular thickness. Prospective study with a large number of patients is needed to clarify the change of macular thickness in relation to glycemic control.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Public Policy > Division of Big Data Science > 1. Journal Articles
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hee Young photo

Kim, Hee Young
공공정책대학 (빅데이터사이언스학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE