Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Novel Consistent Photomicrography Technique Using a Reference Slide Made of Neutral Density Filter

Authors
Kim, Jong YeobKim, Ji WoongSeo, Soo HongKye, Young ChulAhn, Hyo Hyun
Issue Date
5월-2011
Publisher
WILEY-BLACKWELL
Keywords
photomicrography; microscopy; pathology; image processing
Citation
MICROSCOPY RESEARCH AND TECHNIQUE, v.74, no.5, pp.397 - 400
Indexed
SCIE
SCOPUS
Journal Title
MICROSCOPY RESEARCH AND TECHNIQUE
Volume
74
Number
5
Start Page
397
End Page
400
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/112518
DOI
10.1002/jemt.20921
ISSN
1059-910X
Abstract
Obtaining consistent photomicrographic images of pathology slides is not always easy because of many different types and settings of the equipment such as the microscopes and digital cameras. In this study, we developed a photomicrography technique that could acquire consistent images of pathology slides. The neutral density (ND) filter was attached to a transparent glass slide as a reference slide, photographed using consistent settings, and acquired images that harbored all of the areas of gray, white, and black. In the same way, the slide was replaced by the actual pathology slide, and photomicrographed. To simulate different light environment, the above photographic session was repeated using two different light intensities and microscopes. A graphic program was used to adjust levels of the reference slide images and this leveling, or calibration, was saved as a file for each. This file for leveling process was applied to actual subsequent photomicrographic images. The same sites of noncalibrated and calibrated images of the pathology slide were calculated into CIE-LAB or CIE L*a*b* coordinates. Then, the color differences (Delta E*ab) were calculated. As results, in the study using a 50% transmittance ND filter, two original different images were made nearly identical to the unaided eye, especially in two-point (white and gray) and three-point (black, white, and gray) leveling. In comparison of different light intensities, the Delta E*ab of the selected area was 0.9 in two-point leveling. Between different microscopes, 10.7 of Delta E*ab was the smallest value in three-point leveling. This method would be helpful for acquiring consistent photomicrographic images of pathology slides. Microsc. Res. Tech. 74:397-400, 2011. (C) 2010 Wiley-Liss, Inc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seo, Soo Hong photo

Seo, Soo Hong
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE