New Axis-marking Method for a Toric Intraocular Lens: Mapping Method

Authors
Cha, DeoksunKang, Su YeonKim, Seung-HyunSong, Jong-SukKim, Hyo-Myung
Issue Date
5월-2011
Publisher
SLACK INC
Citation
JOURNAL OF REFRACTIVE SURGERY, v.27, no.5, pp.375 - 379
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF REFRACTIVE SURGERY
Volume
27
Number
5
Start Page
375
End Page
379
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/112550
DOI
10.3928/1081597X-20101005-01
ISSN
1081-597X
Abstract
PURPOSE: A new axis-marking method, the mapping method, for toric intraocular lens (IOL) implantation is described, and its accuracy is compared with that of conventional methods. METHODS: For toric IOL implantation, the steepest corneal axis was determined by IOLMaster optical biometer measurement (Carl Zeiss Meditec). Three marking methods for accurate alignment of the IOL astigmatism axis to the steepest corneal axis were evaluated and compared. For method 1, the patient was seated at the surgical table and instructed to gaze at a distant target. Using a toric reference marker, the corneal limbus was marked at the 3-, 6-, and 9-o'clock positions. The goal axis was also marked using a toric axis marker. Method 2 used a horizontal slit beam for reference marking points at 3 and 9 o'clock. Method 3 was the new mapping method, in which an anterior segment photograph was used to identify several reference vessel points and axis marking points and to calculate actual lengths from the reference vessel points to the axis marking points. During surgery, the axis marking points were marked on the limbus of the eye using calipers. The accuracy of the three axis-marking methods was evaluated using anterior segment photographs. RESULTS: With method 1, the average axis-marking error was 3.69 +/- 1.49 degrees. With method 2, the average axis-marking error was 3.14 +/- 1.64 degrees. With method 3, the new mapping method, the average axis-marking error was 2.29 +/- 1.06 degrees. The new mapping method was more accurate than methods 1 and 2 (P <.01 and P=.016, respectively, paired t test). Axis-marking errors of the two conventional methods were not significantly different (P=.061). CONCLUSIONS: The new axis-marking method, which uses distinct conjunctival vessels as a reference point, showed less axis-marking error compared to the conventional methods examined in this study. [J Refract Surg. 2011; 27(5): 375-379.] doi:10.3928/1081597X-20101005-01
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE