Effects of Anodized Implants Coated With Escherichia coli-Derived Recombinant Human Bone Morphogenetic Protein-2 on Osseointegration in Rabbits

Authors
Huh, Jung-BoRyu, Jae-JunKim, Jong-EunKim, Do-WanKim, Sun-JongPark, Young-BumKim, Young-SuLee, Su-YoungLee, Jeong-YeolShin, Sang-Wan
Issue Date
2월-2011
Publisher
KOREAN TISSUE ENGINEERING REGENERATIVE MEDICINE SOC
Keywords
ErhBMP-2; anodized implant; ISQ; histometric analysis; osseointegration
Citation
TISSUE ENGINEERING AND REGENERATIVE MEDICINE, v.8, no.1, pp.62 - 68
Indexed
SCIE
SCOPUS
KCI
OTHER
Journal Title
TISSUE ENGINEERING AND REGENERATIVE MEDICINE
Volume
8
Number
1
Start Page
62
End Page
68
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/113183
ISSN
1738-2696
Abstract
The aim of the present study was to evaluate the effects of anodized implants coated with Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2) on osseointegration using stability tests and histometric analysis. Nine adult New Zealand white rabbits (4.5-5 kg) were used in the study. Thirty-six implants (L, 5.0 mm; D, 4.0 mm) were divided into 2 groups: anodized implants (control group) and ErhBMP-2(1.5 mg/ml concentration, 18 mu g: Cowellmedi Co, Busan, Korea) coated anodized implant (experimental group). In each rabbit, 4 implants were placed in the tibia on both sides. The control and experimental implants were randomly placed in either left or right tibia. The rabbits were sacrificed at the end of the healing period (2, 4 and 12 weeks after operation). The stability of implants was evaluated by resonance frequency analysis. To obtain histometric results, bone to implant contact (BIC) and intra-thread bone density (ITBD) were measured with a light microscope. The ISQ value was significantly greater in the experimental group than in the control group at 12 weeks (P<0.05). ITBD increased over time in the experimental group (P<0.05). Post hoc comparison test analysis showed that a statistically significant change could be found between 2 and 4 weeks in the interaction between the ITBD change by time lapse and an ErhBMP-2 application condition (P=0.033). In this study, a greater degree of ossointegration was observed in the experimental group. ErhBMP-2 coated anodized implants could be used particularly in cases where bone quality is poor or bone volume is insufficient.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ryu, Jae Jun photo

Ryu, Jae Jun
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE