Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Design of Wide-energy-range Neutron Calorimeter for Nuclear Collisions in the Korea Rare-isotope Accelerator

Authors
Hong, ByungsikJhang, GenieJoo, EunahLee, Kyong SeiShim, Hyunha
Issue Date
Feb-2011
Publisher
KOREAN PHYSICAL SOC
Keywords
Neutron calorimeter; Symmetry energy; Equation of state; Heavy-ion collision; Korea rare-isotope accelerator
Citation
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.58, no.2, pp.211 - 222
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF THE KOREAN PHYSICAL SOCIETY
Volume
58
Number
2
Start Page
211
End Page
222
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/113198
DOI
10.3938/jkps.58.211
ISSN
0374-4884
Abstract
We have designed a neutron calorimeter dedicated to the measurement of the nuclear symmetry energy in the planned Korea rare-isotope accelerator. The design was optimized to precisely measure the neutron energy with high efficiency in a wide energy range from about 30 to 300 MeV. The final configuration of the detector is a hybrid of the homogeneous and the sampling calorimeters with a veto counter in the front. The homogeneous part is ideal for measuring low-energy neutrons below similar to 50 MeV whereas the sampling part is efficient for measuring high-energy neutrons. The detection efficiency is estimated to be about 88% for neutron energies larger than 50 MeV and decreases to similar to 78% at 30 MeV. We have estimated the energy resolution as a function of the incident energy based on the time-of-flight method. Assuming an ideal detector performance with null time resolution, the relative energy resolution decreases as the incident neutron energy increases. However, under a more realistic situation with a finite time resolution for the detector, the energy resolution monotonically increases with increasing the neutron energy, following a logarithmic function. Imposing an energy resolution of better than 3% at the highest neutron energy, we find the nominal position of the hybrid calorimeter to be 15 m from the target for a time resolution of 1.0 ns, but the detector needs to be free to move closer to or farther from the target, depending on the physics goal.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Byung sik photo

Hong, Byung sik
College of Science (Department of Physics)
Read more

Altmetrics

Total Views & Downloads

BROWSE