Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The effect and potential of using a temperature controlled separation column with ultra-high pressure microcapillary liquid chromatography/tandem mass spectrometry on proteomic analysis

Authors
Hyung, Seok-WonKim, Min-SikMun, Dong-GiLee, HookeunLee, Sang-Won
Issue Date
2011
Publisher
ROYAL SOC CHEMISTRY
Citation
ANALYST, v.136, no.10, pp.2100 - 2105
Indexed
SCIE
SCOPUS
Journal Title
ANALYST
Volume
136
Number
10
Start Page
2100
End Page
2105
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/114929
DOI
10.1039/c0an00724b
ISSN
0003-2654
Abstract
The microcapillary liquid chromatography (mLC)/tandem mass spectrometry (MS/MS) system has become a prevailing analytical platform in proteomics. Typical proteomic studies aimed at proteomewide identification of peptides and proteins rely heavily on producing an accurate and reproducible solvent-composition gradient throughout microcapillary separation columns to improve LC separation. With the recent advent of targeted proteomic approaches utilizing the LC retention time as a physicochemical parameter for peptides, high reproducibility of LC separation additionally becomes an important factor. In this study, column temperature elevation is utilized to improve reproducibility and separation efficiency of the mu LC-MS/MS system. The simple incorporation of a semi-rigid gas line heater allowed precise control of the temperature of microcapillary columns longer than 70 cm, up to 60 degrees C. Tryptic enolase peptides were used as a standard sample to evaluate the effect of the controlled temperature elevation on the peptide separation efficiency and reproducibility. In addition to the increased reproducibility in peptide elution time due to the controlled column temperature, the temperature elevation resulted in a decrease in the column operation pressure, which, in turn, allowed a higher solvent flow-rate to be employed using the same LC pumps, leading to further improvements in the performance of mLC systems.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science > Department of Chemistry > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher LEE, Sang Won photo

LEE, Sang Won
College of Science (Department of Chemistry)
Read more

Altmetrics

Total Views & Downloads

BROWSE