Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Structure-Function Relationship and Diagnostic Value of Macular Ganglion Cell Complex Measurement Using Fourier-Domain OCT in Glaucoma

Authors
Kim, Na RaeLee, Eun SukSeong, Gong JeKim, Ji HyunAn, Hyong GinKim, Chan Yun
Issue Date
9월-2010
Publisher
ASSOC RESEARCH VISION OPHTHALMOLOGY INC
Citation
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, v.51, no.9, pp.4646 - 4651
Indexed
SCIE
SCOPUS
Journal Title
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
Volume
51
Number
9
Start Page
4646
End Page
4651
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/115817
DOI
10.1167/iovs.09-5053
ISSN
0146-0404
Abstract
PURPOSE. To assess the relationship between visual function and macular ganglion cell complex (GCC) thickness measured by Fourier-domain optical coherence tomography (OCT) and to evaluate the diagnostic value of GCC thickness for detecting early, moderate, and severe glaucoma. METHODS. Participants underwent reliable standard automated perimetry testing and OCT imaging with optic nerve head (ONH) mode and GCC mode within a single day. The relationship between structure and function was evaluated by comparing GCC thickness with mean deviation (MD) and visual field index (VFI), by regression analysis. The results were compared with those obtained for retinal nerve fiber layer (RNFL) thickness. The area under the receiver operating characteristic curve (AUC) was used to determine the relationship between disease severity and glaucomatous changes in RNFL and GCC parameters. RESULTS. One hundred three normal control subjects and 138 patients with glaucoma were included in the present study. Compared with linear models, second-order polynomial models better described the relationships between GCC thickness and MD (P < 0.001), and between GCC thickness and VFI (P < 0.001). A GCC pattern parameter, global loss volume (GLV), had the highest AUC for detecting early glaucoma. The AUC of mean GCC thickness for early glaucoma was higher than that of mean RNFL; however, the difference was not significant (P = 0.330). CONCLUSIONS. A curvilinear function best described the relationship between VF sensitivity and GCC thickness. Macular GCC thickness and RNFL thickness showed similar diagnostic performance for detecting early, moderate, and severe glaucoma. (Invest Ophthalmol Vis Sci. 2010; 51: 4646-4651) DOI: 10.1167/iovs.09-5053
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE