Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Electrochemical detection of vascular endothelial growth factors (VEGFs) using VEGF antibody fragments modified Au NPs/ITO electrode

Authors
Kim, Gang-IlKim, Kyung-WooOh, Min-KyuSung, Yun-Mo
Issue Date
15-3월-2010
Publisher
ELSEVIER ADVANCED TECHNOLOGY
Keywords
Vascular endothelial growth factors (VEGFs); ITO; Antibody fragments; Electrochemical immunoassay; Cyclic voltammetry (CV); Differential pulse voltammetry (DPV)
Citation
BIOSENSORS & BIOELECTRONICS, v.25, no.7, pp.1717 - 1722
Indexed
SCIE
SCOPUS
Journal Title
BIOSENSORS & BIOELECTRONICS
Volume
25
Number
7
Start Page
1717
End Page
1722
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/116802
DOI
10.1016/j.bios.2009.12.015
ISSN
0956-5663
Abstract
A new electrochemical technique for the detection of vascular endothelial growth factors (VEGFs) as a cancer-related biomarker is presented in this paper. Gold nanoparticles (Au NPs) were self-assembled onto an indium tin oxide (ITO) electrode to prepare a modified sandwich type electrochemical immunoassay platform. VEGF antibodies were cleaved into two half-fragments by 2-mercaptoethylamine-HCl (2-MEA) and the fragments were immobilized onto the Au NP substrates by their thiol groups. Through this strategy, randomly oriented attachment of antibodies was prevented which frequently occurs in a general use of whole antibody and reduces the number of available sites for the attachment of target molecules. VEGF target molecules were applied to the immunoelectrodes and they combined with the antibody fragments covering the Au NP electrode, forming antigen-antibody complexes. Then, ferrocene-tagged antibodies, which release electrons under a proper applied potential, were added to the system and they combined with the VEGF molecules pre-attached to the antibody fragments. The redox current of ferrocene measured by the differential pulse voltammetry (DPV) increased almost linearly from 1.27 x 10(-4) to 4.17 x 10(-4) A according to the increase in the concentration of the VEGF target molecules from 100 to 600 pg/ml. The measured current values represent the concentration of the VEGF since they are proportional to the number of ferrocene molecules which is in turn proportional to the concentration of VEGF target molecules. Using this modified sandwich immunoassay with the Au NP/ITO electrode, VEGFs as low as 100 pg/ml were detected with high specificity. (C) 2009 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical and Biological Engineering > 1. Journal Articles
College of Engineering > Department of Materials Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Sung, Yun Mo photo

Sung, Yun Mo
공과대학 (신소재공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE