Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of Internal Anterior Chamber Diameter Imaging Modalities: 35-MHz Ultrasound Biomicroscopy, Visante Optical Coherence Tomography, and Pentacam

Authors
Kim, Sang-KyoonKim, Hyo-MyungSong, Jong-Suk
Issue Date
2월-2010
Publisher
SLACK INC
Citation
JOURNAL OF REFRACTIVE SURGERY, v.26, no.2, pp.120 - 126
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF REFRACTIVE SURGERY
Volume
26
Number
2
Start Page
120
End Page
126
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/117076
DOI
10.3928/1081597X-20100121-07
ISSN
1081-597X
Abstract
PURPOSE: To compare the internal diameter of the anterior chamber among three different imaging modalities: 35-MHz ultrasound biomicroscopy (UBM), Visante optical coherence tomography (OCT), and Pentacam, and to compare the internal diameters with white-to-white (WTW) distance measured by Orbscan. METHODS: The internal horizontal anterior chamber diameter was measured in 20 normal eyes using 35-MHz UBM (Optikon), Visante OCT (Carl Zeiss Meditec), and Pentacam (Oculus Inc). The mean horizontal anterior chamber diameters were compared, and the correlations between each pair of two different methods were evaluated. Horizontal WTW distance was measured by Orbscan Ilz (Bausch & Lomb-Orbtek Inc) and then correlated with the measurements of internal anterior chamber diameter. RESULTS: The mean horizontal anterior chamber diameter was 10.99 +/- 0.47 mm with UBM, 11.70 +/- 0.47 mm with OCT, and 11.86 +/- 0.45 mm with Pentacam. Ultrasound biomicroscopy measurements were significantly different than those of OCT and Pentacam (P<.001 for both). However, no significant difference was found between OCT and Pentacam (P=.19). Regarding the correlations between each pair of two different methods, UBM and OCT showed significant correlation (r=0.848, P<.001), but there was no significant correlation between OCT and Pentacam (r=0.403, P=.078), even though the mean values were similar. In the Bland-Altman plots, the range of agreement was 0.51 mm between OCT and UBM, and 0.99 mm between Pentacam and OCT. CONCLUSIONS: Although the internal anterior chamber diameters measured by 35-MHz UBM were significantly smaller than those measured by Visante OCT and Pentacam, the measurements of UBM and Visante OCT showed significant correlation and good agreement with each other. Pentacam showed poor correlation with other measurements. [J Refract Surg. 2010;26:120-126.] doi:10.3928/1081597X-20100121-07
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE