R-600a 및 R-134a를 공용으로 사용한 소형 냉동사이클의 성능 특성 최적화에 대한 실험적 연구An Experimental Study on the Optimization of the Performance Characteristics of a Refrigeration System Using R-600a and R-134a
- Other Titles
- An Experimental Study on the Optimization of the Performance Characteristics of a Refrigeration System Using R-600a and R-134a
- Authors
- 장의성; 윤원재; 정현준; 정해원; 김용찬
- Issue Date
- 2010
- Publisher
- 대한설비공학회
- Keywords
- Household refrigerator(가정용 냉장고); R-600a(이소부탄); R-134a; COP(성능계수)
- Citation
- 설비공학 논문집, v.22, no.5, pp.268 - 274
- Indexed
- KCI
- Journal Title
- 설비공학 논문집
- Volume
- 22
- Number
- 5
- Start Page
- 268
- End Page
- 274
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/117713
- ISSN
- 1229-6422
- Abstract
- ABSTRACT:Because both R-134a and R-600a are used as a refrigerant of a household refrigerator in the global market, the home-appliance industry needs an optimized cycle for both refrigerants. The objective of this study is to provide the design guideline on the optimization of a refrigeration system using both refrigerants. For both refrigerants, the performance characteristics of the refrigeration system were tested by varying refrigerant charge amount, capillary tube length, suction diameter and SLHX length. The tested refrigeration system was optimized at the refrigerant charge of 60g and the capillary tube length of 3600㎜ with R-134a, and the refrigerant charge of 34g and the capillary tube length of 3900㎜ with R-600a. The COP increased from 1.63 to 1.68 for R-134a and increased from 1.37 to 1.48 for R-600a, respectively, by applying the suction diameter expansion. In addition, the COP of the R-134a and R-600a system decreased by 2.3∼2.4% as the SLHX length decreased by 300㎜.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > Department of Mechanical Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.