Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

광범위한 안와파열골절에서 Titanium Mesh Plate와 Porous Polyethylene (Medpor ®) 동시 사용의 유용성Treatment of Blow-out Fractures Using Both Titanium Mesh Plate and Porous Polyethylene(Medpor ®)

Other Titles
Treatment of Blow-out Fractures Using Both Titanium Mesh Plate and Porous Polyethylene(Medpor ®)
Authors
구자혜원창훈동은상윤을식
Issue Date
2010
Publisher
대한두개안면성형외과학회
Keywords
Blowout fracture; Titanium mesh plate; Porous polyethylene
Citation
Archives of Craniofacial Surgery, v.11, no.2, pp.85 - 90
Indexed
KCI
OTHER
Journal Title
Archives of Craniofacial Surgery
Volume
11
Number
2
Start Page
85
End Page
90
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/117861
ISSN
2287-1152
Abstract
Purpose: The goals of a blow-out fracture reconstruction are to restore the osseous continuity, provide support for the orbital contents and prevent functional and anatomic defects. Over the past several years,a range of autogenous and synthetic implants have been used extensively in orbital reconstructions. None of these implants have any absolute indications or contraindications in certain clinical settings. However,in extensive blow-out fractures, it is difficult to restore support of the orbital contents, which can cause more complications, such as enophthalmos. This study examined the clinical outcomes of extensive or comminuted blow-out fractures that were reconstructed by the simultaneous use of a titanium mesh plate and Medpor . Methods: Eighty six patients with extensive orbital fractures, who were admitted between March 1999and February 2007, were reviewed retrospectively. The patients’ chart and CT were inspected for review. Twenty three patients were operated on with both a titanium mesh plate (Matrix MIDFACE pre-formed orbital plate, Synthes, USA) and Medpor (Porex, GA, USA). The patients underwent pre-operative CT scans to evaluate the fracture site and measure the area of the fracture. A transconjunctival approach was used, and titanium mesh plates were inserted subperiosteally with screw fixation. Medpor was inserted above the titanium mesh plate. The patients were evaluated post-operatively for enophthalmos,diplopia, sensory disturbances and eyeball movement for a period of at least 6 months. Results: No implant-related complications were encountered during the follow-up period. Enophthalmos occurred in 1 patient, 1 patient had permanent sensory disturbance, and 3 patients complained of ocular pain and fatigue, which recovered without treatment. Although there were no significance differences between groups, the use of 2 implants had fewer complications. Therefore, it can be an alternative method for treating blow out fractures. Conclusion: The use of both a titanium mesh plate and Medpor simultaneously may be a safe and acceptable technique in the reconstruction of extensive blow-out fractures. (J Korean Cleft Palate Craniofac Assoc 11: 85, 2010)
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Dhong, Eun Sang photo

Dhong, Eun Sang
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE