Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Analysis of four pesticides, isoproturon, phenmedipham, pyridate and nitenpyram residues by high-performance liquid chromatography with diode-array detector

Full metadata record
DC Field Value Language
dc.contributor.authorYang, S.-Y.-
dc.contributor.authorKoo, Y.-C.-
dc.contributor.authorWang, Z.-
dc.contributor.authorHeo, K.-
dc.contributor.authorKim, H.-
dc.contributor.authorAn, E.-M.-
dc.contributor.authorShin, H.-S.-
dc.contributor.authorLee, J.-W.-
dc.contributor.authorLee, K.-W.-
dc.date.accessioned2021-09-08T09:16:27Z-
dc.date.available2021-09-08T09:16:27Z-
dc.date.created2021-06-17-
dc.date.issued2010-
dc.identifier.issn1226-3311-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/118299-
dc.description.abstractA method for the determination of four pesticide compounds, urea (isoproturon), bis-carbamate (phenmedipham), thiocarbamate (pyridate) and vinyllidenediamine (nitenpyram) were examined and analyzed by HPLC with C-18 column (250 mm×4.6 mm, 5 μm diameter particle size). Mobile phase consisted of deionized water, acetonitrile and 50 mM KH2PO4 (pH 2.5). Isoproturon and phenmedipham analytical condition was isocratic elution of the column with 50% solvent A (acetonitrile) and 50% solvent B (deionized water); pyridate was 85% solvent A (acetonitrile) and 15% solvent B (deionized water) at a flow rate of 1 mL/min; and nitenpyram analytical condition was 90% solvent A (50 mM KH 2PO 4, pH 2.5) and 10% solvent B (acetonitrile) at a flow rate of 1 mL/min. In results, retention times were 6.12, 8.63, 9.40 and 12.76 min for isoproturon, phenmedipham, pyridate and nitenpyram, respectively. All injection volumes were 10 μL and the limit of quantitation was 0.05 mg/kg for four pesticide compounds, respectively. Recovery rate test was performed with three farm products, rice, apple and soybean. Four pesticide compounds were spiked at concentrations of 0.05, 0.1 and 0.5 mg/kg. The recovery rates were ranged from 70.18% to 118.08% and the standard deviations of all experiments were within 10%.-
dc.languageKorean-
dc.language.isoko-
dc.publisherKorean Society of Food Science and Nutrition-
dc.titleAnalysis of four pesticides, isoproturon, phenmedipham, pyridate and nitenpyram residues by high-performance liquid chromatography with diode-array detector-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, K.-W.-
dc.identifier.doi10.3746/jkfn.2010.39.8.1165-
dc.identifier.scopusid2-s2.0-84867276445-
dc.identifier.bibliographicCitationJournal of the Korean Society of Food Science and Nutrition, v.39, no.8, pp.1165 - 1170-
dc.relation.isPartOfJournal of the Korean Society of Food Science and Nutrition-
dc.citation.titleJournal of the Korean Society of Food Science and Nutrition-
dc.citation.volume39-
dc.citation.number8-
dc.citation.startPage1165-
dc.citation.endPage1170-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001470936-
dc.description.journalClass1-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorAnalysis-
dc.subject.keywordAuthorHPLC-
dc.subject.keywordAuthorIsoproturon-
dc.subject.keywordAuthorNitenpyram-
dc.subject.keywordAuthorPesticide-
dc.subject.keywordAuthorPhenmedipham-
dc.subject.keywordAuthorPyridate-
dc.subject.keywordAuthorResidue-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biotechnology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Kwang Won photo

Lee, Kwang Won
융합생명공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE