Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

지중 순환수 유량 변화에 따른 지열원 히트펌프 시스템의 성능 특성 연구Influence of the Secondary Fluid Flow Rate on the Performance of a GSHP System

Other Titles
Influence of the Secondary Fluid Flow Rate on the Performance of a GSHP System
Authors
이준엽정진택우정선최종민
Issue Date
2010
Publisher
대한설비공학회
Keywords
GSHP(지열원 히트펌프 시스템); GLHX(지중 열교환기); COP(성능계수); Flow rate(유량); Load(부하)
Citation
설비공학 논문집, v.22, no.10, pp.649 - 656
Indexed
KCI
Journal Title
설비공학 논문집
Volume
22
Number
10
Start Page
649
End Page
656
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/118490
ISSN
1229-6422
Abstract
The aim of this study is to investigate the influence of the secondary fluid flow rate through GLHX on a GSHP system with vertical single U-tube type GLHXs. The COP of a GSHP system with large flow rate was lower than it with small flow rate due to large power consumption of ground loop circulating pump. It is suggested that the heat pump unit with high COP and low flow rate through the GLHX have to be selected in order to enhance the performance of the system and reduce the length of GLHX.