Experimental analysis of a dimensionless number in the cathode channels of a polymer electrolyte membrane fuel cell with different head losses

Authors
Han, S. H.Kim, K. R.Ahn, D. K.Choi, Y. D.
Issue Date
2010
Publisher
SAGE PUBLICATIONS LTD
Keywords
polymer electrolyte membrane fuel cell; flooding; stoicbiometry; dimensionless number; mass flowrate; current density
Citation
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, v.224, no.C1, pp.95 - 108
Indexed
SCIE
SCOPUS
Journal Title
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE
Volume
224
Number
C1
Start Page
95
End Page
108
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/118699
DOI
10.1243/09544062JMES1757
ISSN
0954-4062
Abstract
This Study investigates the effects of stoichiometry, humidity, cell temperature, and pressure on the performance and the flooding of the proton exchange membrane fuel cell. Values of stoichiometry are 1.5, 2.0, and 2.5 at cell temperatures of 50, 55, and 60 degrees C, respectively This Study shows that the dimension less flooding value (FV)is a function of the stoichiometry, humidity, temperature, and pressure. The FV is calculated by using the measured values of temperature, bumidity, pressure, and flowrate of the cathode. The effect of the dimensionless number on the flooding of the cathode in the proton exchange membrane fuel cell is analysed in this Study. The effects of air stoichiometry, cell temperature, and air humidity are also discussed in this article.