Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Immuno-chromatographic Analysis for HPV-16 and 18 E7 Proteins as a Biomarker of Cervical Cancer Caused by Human Papillomavirus

Authors
Kim, Joo-HoCho, Il-HoonSeo, Sung-MinKim, Ji-SookOh, Kyu-HaKang, Heun-SooKim, In-GyuPaek, Se-Hwan
Issue Date
20-12월-2009
Publisher
WILEY-V C H VERLAG GMBH
Keywords
Rapid test; Papillomaviruses; E7 protein as biomarker; Specimen stability; Cervix cancer
Citation
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, v.30, no.12, pp.2999 - 3005
Indexed
SCIE
SCOPUS
KCI
Journal Title
BULLETIN OF THE KOREAN CHEMICAL SOCIETY
Volume
30
Number
12
Start Page
2999
End Page
3005
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/118732
DOI
10.5012/bkcs.2009.30.12.2999
ISSN
0253-2964
Abstract
Among the more than 120 different types of human papillomavirus (HPV), types 16 and 18 have been known to be high risk agents that cause cervical cancer. We examined, in an immuno-chromatographic analysis, the potential of using the early gene product. E7 protein, as a diagnostic marker of cervical cancer caused by HPV. We developed monoclonal antibodies specific to HPV-16 and 18 E7 proteins that were produced from bacterial cells using, gene recombinant technology. For each E7 protein, the optimal antibody pair was selected using the immuno-chromatographic sandwich-type binding system based on the lateral flow through membrane pores. Under these conditions, this rapid testing assay had a detection capability as low as 2 ng/mL of E7 protein. Furthermore, since viral analysis required the host cell to be lysed using chemicals such as detergents, it was possible that the E7 protein was structurally damaged during this process, which would result in a decrease in detection sensitivity. Therefore, we examined the detrimental effects caused by different detergents on the E7 protein using HeLa cells as the host. In these experiments, we found that the damage caused by the detergent, nonylphenylpolyethylene glycol (NP-40), was minimal relative to Triton X-100 commonly used or the cell lysis. Temperature also affected the stability oldie E7 protein, and we found that the E7 protein was stabilized at 4 T. for about 2 h, which was 4 times longer than at room temperature. Finally, a HPV-infected cervical cancer cell line, which was used as a real sample model, was treated using the optimized conditions and the presence of E7 proteins were analyzed by immuno-chromatography. The results of this experiment demonstrated that this rapid test could specifically detect HPV-infected samples.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Department of Biotechnology and Bioinformatics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE