Droplet-based magnetically activated cell separation: analysis of separation efficiency based on the variation of flow-induced circulation in a pendent drop
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Youngho | - |
dc.contributor.author | Lee, Sang Ho | - |
dc.contributor.author | Kim, Byungkyu | - |
dc.date.accessioned | 2021-09-08T11:09:13Z | - |
dc.date.available | 2021-09-08T11:09:13Z | - |
dc.date.created | 2021-06-11 | - |
dc.date.issued | 2009-12 | - |
dc.identifier.issn | 1618-2642 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/118851 | - |
dc.description.abstract | Under the assumption that separation efficiencies are mainly affected by the velocity of flow-induced circulation due to buffer injection in a pendent drop, this paper describes an analysis of the separation efficiency of a droplet-based magnetically activated cell separation (DMACS) system. To investigate the velocity of the flow-induced circulation, we supposed that numerous flows in a pendent drop could be considered as a "theoretically normalized" flow (or conceptually normalized flow, CNF) based on the Cauchy-Goursat theorem. With the morphological characteristics (length and duration time) of a pendent drop depending on the initial volume, we obtained the velocities of the CNF. By measuring the separation efficiencies for different initial volumes and by analyzing the separation efficiency in terms of the velocity of the CNF, we found that the separation efficiencies (in the case of a low rate of buffer injection; 5 and 15 mu l center dot min(-1)) are mainly affected by the velocity of the CNF. Moreover, we confirmed that the phenomenological features of a pendent drop cause a fluctuation of its separation efficiencies over a range of specific volumes (initial volumes ranging from 40 to 80 A mu l), because of the "sweeping-off" phenomenon, that is, positive cells gathered into the positive fraction are forced to move away from the magnetic side by flow-induced circulation due to buffer injection. In addition, from the variation of the duration time, that is, the interval between the beginning of injection of the buffer solution and the time at which a pendent drop detaches, it could also be confirmed that a shorter duration time leads to decrease of the number of positive cells in negative fraction regardless of the rate of buffer injection (5, 15, and 50 mu l center dot min(-1)). Therefore, if a DMACS system is operated with a 15 mu l center dot min(-1) buffer injection flow rate and an initial volume of 80 mu l or more, we would have the best efficiency of separation in the negative fraction. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SPRINGER HEIDELBERG | - |
dc.subject | MANIPULATION | - |
dc.subject | FABRICATION | - |
dc.subject | MICROCOILS | - |
dc.title | Droplet-based magnetically activated cell separation: analysis of separation efficiency based on the variation of flow-induced circulation in a pendent drop | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Sang Ho | - |
dc.identifier.doi | 10.1007/s00216-009-3131-z | - |
dc.identifier.wosid | 000272017000050 | - |
dc.identifier.bibliographicCitation | ANALYTICAL AND BIOANALYTICAL CHEMISTRY, v.395, no.7, pp.2415 - 2421 | - |
dc.relation.isPartOf | ANALYTICAL AND BIOANALYTICAL CHEMISTRY | - |
dc.citation.title | ANALYTICAL AND BIOANALYTICAL CHEMISTRY | - |
dc.citation.volume | 395 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 2415 | - |
dc.citation.endPage | 2421 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Biochemistry & Molecular Biology | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Biochemical Research Methods | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.subject.keywordPlus | MANIPULATION | - |
dc.subject.keywordPlus | FABRICATION | - |
dc.subject.keywordPlus | MICROCOILS | - |
dc.subject.keywordAuthor | Cell separation | - |
dc.subject.keywordAuthor | Droplet-based magnetically activated cell separation | - |
dc.subject.keywordAuthor | Flow-induced circulation | - |
dc.subject.keywordAuthor | Pendent drop | - |
dc.subject.keywordAuthor | Magnet | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.