Abstract
The dynamics of inkjet droplet of non-Newtonian fluid on glass substrates was investigated experimentally and compared with that of Newtonian fluid. The non-Newtonian fluids used here were 100ppm solutions of polyethylene oxide (300k, 600k and 900k) dissolved in the 1: 1 mixture of water and glycerin. Weber number (We) was 2-35 and Ohnesorge number was fixed at 0.057 +/- 0.003. The wettability of solid substrate was also varied. The diameter of inkjet droplets in the present study was about 50 mu m and was much smaller than the size of the previous studies on drop impact. Due to the development of a thin and long thread at the rear of the main drop the jetting window of polymer solution was much narrower than that of Newtonian fluid, and hence the experimental range of Weber number was restricted. The impact scenarios of non-Newtonian inkjet droplets were found to be qualitatively different from those of Newtonian droplets during the receding phase while they were almost the same as the Newtonian fluid case during the kinematic phase. The spreading diameter at the equilibrium was well correlated with the modified Weber number (We'=We/(1 - cos theta(eq))) as in the case of Newtonian fluid, where theta(eq) is the equilibrium contact angle. The similarity or disparity between the Newtonian and non-Newtonian cases was discussed considering the conformation of polymer chains during each stage of drop deformation. (C) 2009 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical and Biological Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE