Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Heat Transfer to the Implant-Bone Interface During Preparation of a Zirconia/Alumina Abutment

Authors
Huh, Jung-BoEckert, Steven E.Ko, Seok-MinChoi, Yong-Geun
Issue Date
7월-2009
Publisher
QUINTESSENCE PUBLISHING CO INC
Keywords
heat generation; implant abutment preparation; zirconia/alumina abutment
Citation
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, v.24, no.4, pp.679 - 683
Indexed
SCIE
SCOPUS
Journal Title
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS
Volume
24
Number
4
Start Page
679
End Page
683
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/119704
ISSN
0882-2786
Abstract
Purpose: Excessive heat at the implant-bone interface may compromise osseointegration. This study examined the heat generated at the implant surface during preparation of a zirconia/alumina abutment in vitro. Materials and Methods: Sixty zirconia/alumina abutments were randomized into 12 experimental groups. The abutments were connected to implants and embedded in an acrylic resin block in a 37 degrees C water bath. The abutments were reduced by 1 mm in height over a period of 1 minute with a high-speed handpiece and then polished for 30 seconds with a low-speed handpiece, both with and without an air/water coolant. Temperatures were recorded via thermocouples at the cervical, middle, and apical part of the implant surfaces. The Mann-Whitney rank-sum test was used to assess the statistical significance of the difference in temperature between the abutment/implant complexes altered with and without coolant. Results: The 1-mm reduction with the high-speed handpiece without coolant resulted in a maximum temperature of 41.22 degrees C at the cervical portion of the implant. Three of four temperatures above 40 degrees C were observed at the cervical part of the implant following use of the high-speed handpiece without coolant. The temperature difference between "with coolant" and "without coolant" during both low-speed polishing and high-speed reduction was statistically significant at the cervical portion of the implant (P = .009). In contrast, the temperature difference between "with coolant" and "without coolant" during both low-speed polishing and high-speed reduction was not statistically significant at the middle and apical parts of the implant (P > .05). Conclusions: Preparation of a zirconia/alumina abutment caused an increase in temperature within the implant, but this temperature increase did not reach the critical levels described in the implant literature. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:679-683
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE