Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Online Detection of High-Resistance Connections in the Incoming Electrical Circuit for Induction Motors

Authors
Yun, JanghoCho, JintaeLee, Sang BinYoo, Ji-Yoon
Issue Date
Mar-2009
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
AC electric machines; condition monitoring; diagnostics; electrical distribution system; high-resistance (R) connection; induction machine; symmetrical components
Citation
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, v.45, no.2, pp.694 - 702
Indexed
SCIE
SCOPUS
Journal Title
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS
Volume
45
Number
2
Start Page
694
End Page
702
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/120508
DOI
10.1109/TIA.2009.2013576
ISSN
0093-9994
Abstract
A high-resistance (R) connection in an induction-motor electrical circuit results in localized overheating and supply-voltage unbalance, which leads to a decreased efficiency and reliability and an increased fire hazard in the electrical distribution system and motor. Therefore, it is important to monitor and correct high-R connections for a reliable, efficient, and safe operation of the industrial facility. This paper focuses on the development of an online technique for detecting poor connections based on monitoring the asymmetry in the voltage and current measurement. The development of the technique begins with the derivation of the dynamic model of an induction motor with high-R connections. Based on the analysis of the model, two approaches for detecting poor contacts using the negative-sequence current and zero-sequence voltage are proposed. In addition to detecting the existence of faults, the location and severity of the fault can also be determined using the proposed method. An experimental study on a 10-hp induction machine under simulated and realistic high-R conditions shows that the proposed techniques provide a simple low-cost solution for reliably detecting poor contact problems at an early stage. It is also shown that the severity and location of the high-R contact fault can be assessed with high accuracy.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sang bin photo

Lee, Sang bin
College of Engineering (School of Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE