Indoor air quality investigation according to age of the school buildings in Korea

Authors
Yang, WonhoSohn, JongryeulKim, JihwanSon, BusoonPark, Jinchul
Issue Date
Jan-2009
Publisher
ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD
Keywords
School; Indoor air quality; Season; New construction
Citation
JOURNAL OF ENVIRONMENTAL MANAGEMENT, v.90, no.1, pp.348 - 354
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF ENVIRONMENTAL MANAGEMENT
Volume
90
Number
1
Start Page
348
End Page
354
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/120833
DOI
10.1016/j.jenvman.2007.10.003
ISSN
0301-4797
Abstract
Since the majority of schools are housed in buildings dating from the 1960s and 1970s, a comprehensive construction and renovation program of school buildings has been carried Out to improve the educational conditions in Korea. However, classrooms and computer rooms, with pressed wood desks, chairs and furnishings, as well as construction materials, might have negative effects on the indoor air quality. Furthermore, most schools have naturally ventilated classrooms. The purpose of this study was to characterize the concentrations of different indoor air pollutants within Korean schools and to compare their indoor levels within schools according to the age of school buildings. Indoor and outdoor air samples of carbon monoxide (CO), carbon dioxide (M), particulate matter (PM10), total microbial count (TBC), total volatile organic compounds (TVOCs) and formaldehyde (HCHO) were obtained during summer, autumn and winter from three sites a classroom, a laboratory and a computer classroom at 55 different schools. The selection of the schools was based on the number of years since the schools had been constructed. The problems causing indoor air pollution at the schools were chemicals emitted by building materials or furnishings, and insufficient ventilation rates. The I/O ratio for HCHO was 6.32 during the autumn, and the indoor HCHO concentrations (mean = 0.16 ppm) in schools constructed within I year were significantly higher than the Korean Indoor Air Standard, indicating that schools have indoor sources of HCHO. Therefore, increasing the ventilation rate by means of a mechanical system and the use of low-emission furnishings can play key roles in improving the indoor air quality within schools. (C) 2007 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
College of Health Sciences (Division of Health Policy and Management)
Read more

Altmetrics

Total Views & Downloads

BROWSE