Validation for capture anion exchange chromatography process in r-hGH manufacturing

Authors
Min, Byeong JoKang, Seong WooSong, Yoon SeokLee, Jong HoKim, Seung WookPark, ChulhwanKim, Chan Wha
Issue Date
Aug-2008
Publisher
ELSEVIER SCI LTD
Keywords
process validation; human growth hormone (hGH); acceptance criteria; anion exchange chromatography; Escherichia coli; purification
Citation
PROCESS BIOCHEMISTRY, v.43, no.8, pp.808 - 815
Indexed
SCIE
SCOPUS
Journal Title
PROCESS BIOCHEMISTRY
Volume
43
Number
8
Start Page
808
End Page
815
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/122947
DOI
10.1016/j.procbio.2008.03.011
ISSN
1359-5113
Abstract
The first anion exchange chromatography in the four chromatography steps of the r-hGH manufacturing process was validated in this study, using a validation protocol consistent with both policy and standard operation procedure (SOP). The first anion exchange chromatography was conducted with a DEAE Sepharose Fast Flow Resin equilibrated with 50 mM Tris-HCl buffer (pH 8.2). The activated r-hGH solution obtained from the inclusion body was loaded onto a column and eluted with a linear gradient of 80-300 mM Tris-HCl buffer (pH 8.2) at a flow rate of 25 L/h. Several buffer solutions used in the first anion exchange chromatography were first validated and satisfied the acceptance criteria preestablished as follows; pH: 8.2, endotoxin: <0.8 EU/mL, bioburden test: negative. Three consecutive lots of crude r-hGH solutions were generated via anion exchange chromatography, which was operated within the operating parameters pre-established via in-process control. When the intermediate products (crude Met-hGH solutions) of all three lots were assessed in accordance with the pre-established sampling plan and quality control tests, all three tested lots satisfied the acceptance criteria preestablished for the following purification process as fallows: endotoxin: <= 350 EU/mg, ECP: <= 42 ppm, IEF: same removal distance, r-hGH content in Native-PAGE: >73%, purity by HPLC: >= 86%, purification yield by UV scanning: 32-36%. Therefore, the first anion chromatography process was well validated in this study, and consistently yields crude r-hGH solutions that fulfill the pre-established criteria for the next purification process. (C) 2008 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical and Biological Engineering > 1. Journal Articles
College of Life Sciences and Biotechnology > Division of Life Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE