Cu2+-induced intermolecular static excimer formation of pyrenealkylamine
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Hyun Jung | - |
dc.contributor.author | Hong, Jooyeon | - |
dc.contributor.author | Hong, Areum | - |
dc.contributor.author | Ham, Sihyun | - |
dc.contributor.author | Lee, Joung Hae | - |
dc.contributor.author | Kim, Jong Seung | - |
dc.date.accessioned | 2021-09-09T08:25:13Z | - |
dc.date.available | 2021-09-09T08:25:13Z | - |
dc.date.created | 2021-06-10 | - |
dc.date.issued | 2008-05-15 | - |
dc.identifier.issn | 1523-7060 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/123535 | - |
dc.description.abstract | Synthesis of monopyrenylalkylamine derivative 1 and its fluorescence behavior for Cu2+ in H2O/CH3CN (1:1, v/v) were investigated. Upon Cu2+ binding, 1, bearing a sulfonamide group, exhibited a marked excimer emission at 455 nm along with a weak monomer emission at 375 nm. The excimer emission, driven by formation of an intermolecular pyrenyl static excimer upon Cu2+ binding to the sulfonamide group, is rationalized by experimental and theoretical DFT calculation results. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | AMER CHEMICAL SOC | - |
dc.subject | SELECTIVE FLUORESCENT SENSOR | - |
dc.subject | CU-II | - |
dc.subject | CHEMOSENSOR | - |
dc.subject | DESIGN | - |
dc.subject | RATIOMETRY | - |
dc.subject | PROBE | - |
dc.subject | IONS | - |
dc.title | Cu2+-induced intermolecular static excimer formation of pyrenealkylamine | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Jong Seung | - |
dc.identifier.doi | 10.1021/ol800475d | - |
dc.identifier.scopusid | 2-s2.0-47049102373 | - |
dc.identifier.wosid | 000255694100022 | - |
dc.identifier.bibliographicCitation | ORGANIC LETTERS, v.10, no.10, pp.1963 - 1966 | - |
dc.relation.isPartOf | ORGANIC LETTERS | - |
dc.citation.title | ORGANIC LETTERS | - |
dc.citation.volume | 10 | - |
dc.citation.number | 10 | - |
dc.citation.startPage | 1963 | - |
dc.citation.endPage | 1966 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Organic | - |
dc.subject.keywordPlus | SELECTIVE FLUORESCENT SENSOR | - |
dc.subject.keywordPlus | CU-II | - |
dc.subject.keywordPlus | CHEMOSENSOR | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordPlus | RATIOMETRY | - |
dc.subject.keywordPlus | PROBE | - |
dc.subject.keywordPlus | IONS | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.