A Non-Intrusive Leakage Flux Based Method for Detecting Rotor Faults in the Starting Transient of Salient Pole Synchronous Motors

Authors
Shaikh, Muhammad FaizanPark, JongsanLee, Sang Bin
Issue Date
6월-2021
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Rotors; Windings; Shock absorbers; Synchronous motors; Induction motors; Bars; Circuit faults; Condition monitoring; damper bar; fault diagnostics; field winding; magnetic flux leakage; motor testing; spectral analysis; wound field synchronous motor
Citation
IEEE TRANSACTIONS ON ENERGY CONVERSION, v.36, no.2, pp.1262 - 1270
Indexed
SCIE
SCOPUS
Journal Title
IEEE TRANSACTIONS ON ENERGY CONVERSION
Volume
36
Number
2
Start Page
1262
End Page
1270
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/127895
DOI
10.1109/TEC.2020.3021207
ISSN
0885-8969
Abstract
Damper and field windings are critical components of wound field synchronous motors (WFSM), where failure can lead to forced outage of the motor and industrial process. Due to the relatively rare presence of WFSMs in industry compared to induction motors, research on fault detection techniques for WFSMs is not as active. Rotor fault detection in WFSMs is also difficult, as synchronous operation leaves damper bars inactive during steady state operation while a small number of shorted field windings do not cause noticeable asymmetry. Therefore, most of the field-wide accepted tests rely on off-line testing or visual inspection of the rotor, or require airgap flux measurements, which necessitate motor disassembly and/or installation of sensors. Hence non-intrusive test methods which do not require motor disassembly are sorely needed to guarantee continued operation of the motor and industrial process. In this article, novel test methods based on the use of the leakage flux measured via search coils placed externally on the motor frame are proposed. A non-intrusive method for detecting and distinguishing damper and field winding faults during motor starting is devised from the time and frequency domain analysis of leakage flux and current. The methods are verified via experimental testing on a 30-kW salient pole WFSM.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sang bin photo

Lee, Sang bin
공과대학 (전기전자공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE