Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Towards a two-dimensional readout of the improved CMS Resistive Plate Chamber with a new front-end electronics

Authors
Meola, S.Samalan, A.Tytgat, M.Zaganidis, N.Alves, G. A.Marujo, F.De Araujo, F. Torres Da SilvaDa Costa, E. M.Damiao, D. De JesusNogima, H.Santoro, A.De Souza, S. FonsecaAleksandrov, A.Hadjiiska, R.Iaydjiev, P.Rodozov, M.Shopova, M.Sultanov, G.Bonchev, M.Dimitrov, A.Litov, L.Pavlov, B.Petkov, P.Petrov, A.Qian, S. J.Cao, P.Kou, H.Liu, Z.Song, J.Zhao, J.Bernal, C.Cabrera, A.Fraga, J.Sarkar, A.Elsayed, S.Assran, Y.El Sawy, M.Mahmoud, M. A.Mohammed, Y.Combaret, C.Gouzevitch, M.Grenier, G.Laktineh, IMirabito, L.Shchablo, K.Bagaturia, ILomidze, D.Lomidze, IBhatnagar, VGupta, R.Kumari, P.Singh, J.Amoozegar, VBoghrati, B.Ebraimi, M.Ghasemi, R.Najafabadi, M. MohammadiZareian, E.Abbrescia, M.Aly, R.Elmetenawee, W.De Filippis, N.Gelmi, A.Iaselli, G.Leszki, S.Loddo, F.Margjeka, IPugliese, G.Ramos, D.Benussi, L.Bianco, S.Piccolo, D.Buontempo, S.Di Crescenzo, A.Fienga, F.De Lellis, G.Lista, L.Paolucci, P.Braghieri, A.Salvini, P.Montagna, P.Riccardi, C.Vitulo, P.Francois, B.Kim, T. J.Park, J.Choi, S. Y.Hong, B.Lee, K. S.Goh, J.Lee, H.Eysermans, J.Estrada, C. UribePedraza, ICastilla-Valdez, H.Sanchez-Hernandez, A.Herrera, C. A. MondragonNavarro, D. A. PerezSanchez, G. A. AyalaCarrillo, S.Vazquez, E.Radi, A.Ahmad, A.Asghar, IHoorani, H.Muhammad, S.Shah, M. A.Crotty, I
Issue Date
4월-2021
Publisher
IOP PUBLISHING LTD
Keywords
Front-end electronics for detector readout; Gaseous detectors; Resistive-plate chambers; Radiation-hard detectors
Citation
JOURNAL OF INSTRUMENTATION, v.16, no.4
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF INSTRUMENTATION
Volume
16
Number
4
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/128352
DOI
10.1088/1748-0221/16/04/C04001
ISSN
1748-0221
Abstract
As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new resistive plate chambers will be installed in the region at low angle with respect to the beam collision axis, in order to improve the detection of muons with a low transverse momentum. High background conditions are expected in this region during the high-luminosity phase of the Large Hadron Collider, therefore an improved-RPC design has been proposed with a new front-end electronics to sustain a higher particle rate capability and better time resolution. A new technology is used in the front-end electronics resulting in low achievable signal detection of 1-20 fC. Crucial in the design of the improved-RPC is the capability of a two-dimensional readout in order to improve the spatial resolution, mainly motivated by trigger requirements. In this work, the first performance results towards this two-dimensional readout are presented, based on data taken on a real-size prototype chamber with two embedded readout planes with orthogonal strips.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Byung sik photo

Hong, Byung sik
이과대학 (물리학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE