Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of Left Atrial Appendage Isolation Using Cardiac MRI after Catheter Ablation of Atrial Fibrillation: Paradox of Appendage ReservoirEvaluation of Left Atrial Appendage Isolation Using Cardiac MRI after Catheter Ablation of Atrial Fibrillation: Paradox of Appendage Reservoir

Other Titles
Evaluation of Left Atrial Appendage Isolation Using Cardiac MRI after Catheter Ablation of Atrial Fibrillation: Paradox of Appendage Reservoir
Authors
Cho HyungjoonCho YongwonShim JaeminChoi Jong-IlKim Young-HoonOh Yu-WhanHwang Sung Ho
Issue Date
Apr-2021
Publisher
대한영상의학회
Keywords
Atrial fibrillation; Catheter ablation; Left atrium; Left atrial appendage; Magnetic resonance imaging
Citation
Korean Journal of Radiology, v.22, no.4, pp.525 - 534
Indexed
SCIE
SCOPUS
KCI
Journal Title
Korean Journal of Radiology
Volume
22
Number
4
Start Page
525
End Page
534
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/129031
DOI
10.3348/kjr.2020.0629
ISSN
1229-6929
Abstract
Objective: To assess the effect of left atrial appendage (LAA) isolation on LAA emptying and left atrial (LA) function using cardiac MRI in patients who underwent successful catheter ablation of atrial fibrillation (AF). Materials and Methods: This retrospective study included 84 patients (mean age, 59 ± 10 years; 67 males) who underwent cardiac MRI after successful catheter ablation of AF. According to the electrical activity of LAA after catheter ablation, patients showed either LAA isolation or LAA normal activity. The LAA emptying phase (LAA-EP, in the systolic phase [SP] or diastolic phase), LAA emptying flux (LAA-EF, mL/s), and LA ejection fraction (LAEF, %) were evaluated by cardiac MRI. Results: Of the 84 patients, 61 (73%) and 23 (27%) patients showed LAA normal activity and LAA isolation, respectively. Incidence of LAA emptying in SP was significantly higher in LAA isolation (91% vs. 0%, p < 0.001) than in LAA normal activation. LAA-EF was significantly lower in LAA isolation (40.1 ± 16.2 mL/s vs. 80.2 ± 25.1 mL/s, p < 0.001) than in LAA normal activity. Furthermore, LAEF was significantly lower in LAA isolation (23.7% ± 11.2% vs. 31.1% ± 16.6%, p = 0.04) than in LAA normal activity. Multivariate analysis demonstrated that the LAA-EP was independent from LAEF (p = 0.01). Conclusion: LAA emptying in SP may be a critical characteristic of LAA isolation, and it may adversely affect the LAEF after catheter ablation of AF.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Yu Whan photo

Oh, Yu Whan
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE