Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study
- Authors
- Lee, Beom-Il; You, Seung-Gyu; You, Seung-Min; Kang, Seen-Young; Kim, Ji-Hwan
- Issue Date
- 2월-2021
- Publisher
- KOREAN ACAD PROSTHODONTICS
- Keywords
- Additive manufacturing; Digital light processing; Rinsing time; Interim crown; Accuracy
- Citation
- JOURNAL OF ADVANCED PROSTHODONTICS, v.13, no.1, pp.24 - 35
- Indexed
- SCIE
SCOPUS
KCI
- Journal Title
- JOURNAL OF ADVANCED PROSTHODONTICS
- Volume
- 13
- Number
- 1
- Start Page
- 24
- End Page
- 35
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/129298
- DOI
- 10.4047/jap.2021.13.1.24
- ISSN
- 2005-7806
- Abstract
- PURPOSE. This study was to evaluate the effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing. MATERIALS AND METHODS. The maxillary right first molar master die was duplicated using a silicone material, while a study die was produced using epoxy resin. Scans of the epoxy resin die were used in combination with CAD software to design a maxillary right first molar interim crown. Based on this design, 24 interim crowns were fabricated with digital light processing. This study examined the trueness and precision of products that were processed with one of the three different post-processing rinsing times (1 min, 5 min, and 10 min). Trueness was measured by superimposing reference data with scanned data from external, intaglio, and marginal surfaces. Precision was measured by superimposing the scan data within the group. The trueness and precision data were analyzed using Kruskal-Wallis, nonparametric, and post-hoc tests, and were compared using a MannWhitney U test with Bonferroni correction (alpha=.05). RESULTS. The trueness of the external and intaglio surfaces of crowns varied significantly among the different rinsing times (P=.004, P=.003), but there was no statistically significant difference in terms of trueness measurements of the marginal surfaces (P=.605). In terms of precision, statistically significant differences were found among the external, intaglio, and marginal surfaces (P=.001). CONCLUSION. Interim crowns rinsed for 10 minutes showed high accuracy.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.