Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Automated immunohistochemical assessment ability to evaluate estrogen and progesterone receptor status compared with quantitative reverse transcription-polymerase chain reaction in breast carcinoma patients

Authors
Jeon, TaesungKim, AereeKim, Chungyeul
Issue Date
Jan-2021
Publisher
KOREAN SOC PATHOLOGISTS
Keywords
Breast neoplasm; Hormone; RNA; messenger; Analysis
Citation
JOURNAL OF PATHOLOGY AND TRANSLATIONAL MEDICINE, v.55, no.1, pp.33 - 42
Indexed
SCOPUS
KCI
Journal Title
JOURNAL OF PATHOLOGY AND TRANSLATIONAL MEDICINE
Volume
55
Number
1
Start Page
33
End Page
42
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/129515
DOI
10.4132/jptm.2020.09.29
ISSN
2383-7837
Abstract
Background: This study aimed to investigate the capability of an automated immunohistochemical (IHC) evaluation of hormonal receptor status in breast cancer patients compared to a well-validated quantitative reverse transcription-polymerase chain reaction (RT-qPCR) method. Methods: This study included 93 invasive breast carcinoma cases that had both standard IHC assay and Oncotype Dx assay results. The same paraffin blocks on which Oncotype Dx assay had been performed were selected. Estrogen receptor (ER) and progesterone receptor (PR) receptor status were evaluated through IHC stains using SP1 monoclonal antibody for ER, and 1E2 monoclonal antibody for PR. All ER and PR immunostained slides were scanned, and invasive tumor areas were marked. Using the Quant-Center image analyzer provided by 3DHISTECH, IHC staining of hormone receptors was measured and converted to histochemical scores (H scores). Pearson correlation coefficients were calculated between Oncotype Dx hormone receptor scores and H scores, and between Oncotype Dx scores and Allred scores. Results: H scores measured by an automated imaging system showed high concordance with RT-qPCR scores. ER concordance was 98.9% (92/93), and PR concordance was 91.4% (85/93). The correlation magnitude between automated H scores and RT-qPCR scores was high and comparable to those of Allred scores (for ER, 0.51 vs. 0.37 [p=.121], for PR, 0.70 vs. 0.72 [p=.39]). Conclusions: Automated H scores showed a high concordance with quantitative mRNA expression levels measured by RT-qPCR.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE