Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Component gap measurement reflects the planned gap balance during total knee arthroplasty more accurately and reliably than bone surface gap measurement

Authors
Shin, Kyun-HoJang, Ki-MoHan, Seung-Beom
Issue Date
2022
Publisher
SPRINGER
Keywords
Total knee replacement; Total knee arthroplasty; Computer-assisted surgeries; Gap measurement; Gap balancing; Laxity
Citation
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, v.30, no.2, pp.584 - 592
Indexed
SCIE
SCOPUS
Journal Title
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
Volume
30
Number
2
Start Page
584
End Page
592
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/130037
DOI
10.1007/s00167-020-06324-7
ISSN
0942-2056
Abstract
Purpose This study aimed to compare the reliability of two gap assessment methods (component and bone surface gap measurement vs. planned gap balance) and identify the contributors to component gaps other than planned gaps. Methods The prospectively collected data for 122 consecutive primary total knee arthroplasties (TKAs; 114 patients). After femoral planning for gap balancing, the medial and lateral planned gaps were calculated (planned gap). The established medial extension and flexion gaps (MEG and MFG, respectively) and lateral extension and flexion gaps (LEG and LFG, respectively) were measured with and without the TKA components (bone surface and component gaps) at 0 degrees and 90 degrees flexion. The intraclass and Pearson correlation coefficients for each gap measurement method were assessed using planned gap values, and multiple linear regression analyses were performed to identify the contributors to component gaps. Results Compared with the bone surface gap measurement, the component gap measurement showed higher reliability and stronger correlation with the planned gap balance for each gap. The changes in the medial posterior femoral offset contributed to the MEG and LEG, whereas those in the joint line height contributed to the LEG. The changes in the hip-knee-ankle angle and lateral posterior femoral offset contributed to the LFG. Conclusion Component gap measurements of the established gap more accurately and reliably reflect the planned gap balance than do bone surface gap measurements. The established gaps are affected by several factors other than femoral planning.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE