Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effects of Different Thickness Combinations of Core and Veneer Ceramics on Optical Properties of CAD-CAM Glass-Ceramics

Authors
Kang, WolPark, Jong-KyoungKim, Woong-ChulKim, Hae-YoungKim, Ji-Hwan
Issue Date
2019
Publisher
HINDAWI LTD
Citation
BIOMED RESEARCH INTERNATIONAL, v.2019
Indexed
SCIE
SCOPUS
Journal Title
BIOMED RESEARCH INTERNATIONAL
Volume
2019
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/131719
DOI
10.1155/2019/5856482
ISSN
2314-6133
Abstract
The goal of this study was to evaluate the effects of different core and veneer thicknesses on the translucency (T%), average light transmittance (T), translucency parameter (TP), contrast ratio (CR), and spectral reflectance (R) of glass-ceramics using a computer-aided design/computer-aided manufacturing (CAD-CAM) process. In all, 42 specimens (11mm x 11mm) were prepared and divided into six groups (n = 7 for each group). Core materials (IPS e.max CAD; IPS Empress CAD, LT A2 shade) of different thicknesses (0.8, 1.0, and 1.2mm) were fabricated. Each veneer material (thicknesses of 0.7, 0.5, and 0.3mm) was combined with its compatible core ceramic. Each core material was overlapped with its corresponding veneer material to obtain a 1.5-mm thickness by using three different combinations: (0.8+0.7), (1.0+0.5), and (1.2+0.3) mm. A spectrophotometer and color data software were used to measure the T%, T, TP, CR, and R values of each ceramic. The results were statistically analyzed using two-way analysis of variables (ANOVA) and regression analysis (p<0.05). Two-way ANOVA revealed that T%, T, TP, and CR were significantly influenced by the different thicknesses of the core-veneer combinations (p<0.001). At a certain thickness, as the veneer thickness increased and core thickness decreased, T and T% all increased. Regression analysis of the ceramic materials indicated a reduction in T and T% for certain core-veneer combinations. Analysis also revealed that T% and T were all affected by different core-veneer combinations. The T% value was 74.31 for the EM group and 72.81 for the EP group when the thickness of the core was 1.2 mm and the veneer was 0.3 mm. The R value of EM2 was lower than EM1 and EM3. In conclusion, the optical properties were influenced by different core-veneer combinations.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE