Prospective, Randomized, Double Blind, Multicenter Study for an Autocrosslinked Polysaccharide Gel to Evaluate Antiadhesive Effect and Safety Compared to Poloxamer/Sodium Alginate After Thyroidectomy

Authors
Kim, Woo YoungLee, Jae BokKim, Hoon YubPark, Pyoung JaeJung, Seung PilLee, Hye YoonCho, Jae-GuPark, Kyoung SikCho, Min Jeng
Issue Date
Sep-2018
Publisher
INT COLLEGE OF SURGEONS
Keywords
Sodium hyaluronate; Surgery-induced tissue adhesions; Thyroid
Citation
INTERNATIONAL SURGERY, v.103, no.9-10, pp.452 - 460
Indexed
SCIE
SCOPUS
Journal Title
INTERNATIONAL SURGERY
Volume
103
Number
9-10
Start Page
452
End Page
460
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/131752
DOI
10.9738/INTSURG-D-17-00065.1
ISSN
0020-8868
Abstract
The aim of the study was to compare the efficacy and safety between an autocrosslinked polysaccharide (ACP) gel (Hyalobarrier) and a poloxamer/sodium alginate (P/SA: Guardix-SG) in preventing adhesions after thyroidectomy and demonstrate the non-inferiority of ACP gel to P/SA. To identify differences of antiadhesive efficacy and safety between the ACP gel and P/SA, we investigated various variables such as the proportion of normal esophageal motility as assessed using marshmallow esophagography, swallowing impairment, adhesion severity and so on. This prospective, randomized, double-blinded, multicenter, phase III study investigated the antiadhesive efficacy and safety of ACP gel compared with those of P/SA for 12 weeks. Subjects were randomly assigned to receive either ACP gel (n= 97) or P/SA (n =96). The primary endpoint was the proportion of normal esophageal motility as assessed using marshmallow esophagography, while the secondary endpoints included swallowing impairment, adhesion severity, laryngoscopic assessment of the vocal cords, and voice range profile. Safety endpoints included adverse events. There was no significant difference between the ACP gel and P/SA groups in the proportion of normal esophageal motility as the primary endpoint (P = 0.7428). In addition, there were no differences in the secondary or safety endpoints between the 2 groups. It was demonstrated that ACP gel was not inferior to P/SA. ACP gel appears both effective and safe for use in preventing adhesions after thyroidectomy.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jae Bok photo

Lee, Jae Bok
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE