Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Tapered reduced deep beam connection for long span steel moment frames

Authors
Alemayehu, Robel WondimuJung, SihwaBae, JaehoonLee, Chang-HwanJu, Young K.
Issue Date
1-10월-2021
Publisher
ELSEVIER SCI LTD
Keywords
Connection; Deep Beam; Finite Element Method; Panel Zone; Reduced Beam Section; Tapered Beam Flange
Citation
ENGINEERING STRUCTURES, v.244
Indexed
SCIE
SCOPUS
Journal Title
ENGINEERING STRUCTURES
Volume
244
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/136089
DOI
10.1016/j.engstruct.2021.112731
ISSN
0141-0296
Abstract
Beam to column connection ductility and beam flexural stiffness are crucial parameters for seismic performance and drift control in moment-resisting frames. However, an increase in beam span and depth to obtain columnfree flexible internal space affects these parameters negatively. In this paper, a new long-span deep beamcolumn connection detail is proposed with improved stiffness and adequate ductility for moment frames in low-to-moderate seismic zones. As panel zones can undergo plastic deformation beyond the joint rotation demand in low-to-moderate seismic zones, the beam flange and panel zone in the proposed connection are proportioned such that a stable yielding occurs in the panel zone and two plastic zones on the beam segment away from the beam-column interface. The beam flanges at the beam-column interface are thickened, widened, and tapered to control beam plastic hinge locations and mitigate distress resulting from significant panel zone plastic deformation. The performance of the proposed connection was evaluated through a full-scale cyclic load test and parametric finite element analysis on a beam-column connection with a 1200 mm deep beam. The test and finite element results showed the formation of plastic hinges at the anticipated locations. Furthermore, the connection exhibited stable hysteresis beyond the minimum rotation limits specified for intermediate moment frames (American code) and ductility class medium (Eurocode). Moreover, the connection effectively allowed balancing between beam and panel zone yielding while hindering beam flange distress associated with significant panel zone plastic deformation. Furthermore, a comparison between the proposed and welded unreinforced flange-welded web connection demonstrated improved ductility, stiffness, moment capacity, and energy dissipation capacity. Additionally, equations were proposed to quantify the improvements, and balance beam and panel zone energy dissipation.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher JU, YOUNG KYU photo

JU, YOUNG KYU
공과대학 (건축사회환경공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE