Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of EI-GC-MS/MS, APCI-LC-MS/MS, and ESI-LC-MS/MS for the Simultaneous Analysis of Nine Nitrosamines Eluted from Synthetic Resins into Artificial Saliva and Health Risk Assessment

Authors
Kim, HyungsooSung, DaekwanYu, HonghyeonJang, DaeyongKoo, YejiLee, SeunghaLim, KyungminChoi, Dalwoong
Issue Date
10월-2021
Publisher
MDPI
Keywords
gas chromatography-tandem mass spectrometry; liquid chromatography-tandem mass spectrometry; method validation; nitrosamines; risk assessment
Citation
TOXICS, v.9, no.10
Indexed
SCIE
SCOPUS
Journal Title
TOXICS
Volume
9
Number
10
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/136122
DOI
10.3390/toxics9100230
ISSN
2305-6304
Abstract
Nitrosamines can be produced during the manufacture of rubber-type products such as pacifiers or the nipples of baby bottles. Humans can be exposed to the nitrosamines in these products when they are eluted into saliva. In this study, we compared the efficiency of electron impact ionization (EI), atmospheric pressure chemical ionization (APCI), and electrospray ionization (ESI) methods for the analysis of nine nitrosamines eluted into artificial saliva. In addition, nine nitrosamines eluted from 54 rubber-type products (rubber, thermoplastic elastomer, thermoplastic polyurethane, and polyurethane) marketed in Korea were monitored. Finally, non-carcinogenic and carcinogenic risk assessments of oral exposure to nine nitrosamines were performed based on the monitoring results. EI-GC-MS/MS performed the best for the simultaneous analysis of these nine nitrosamines with respect to overall linearity, trace analysis limit of detection (less than 1 mu g), recovery (average 108.66 +/- 9.32%), and precision (less than 6%), compared with liquid chromatography-tandem mass spectrometry (LC-MS/MS) (APCI and ESI) methods. Using the EI-GC-MS/MS method, these nine nitrosamines eluted into artificial saliva from 54 rubber-type products were monitored. Based on the monitoring data, risk assessment was performed by calculating the margin of exposure (MOE) for the respective nitrosamines detected. As a result, these nitrosamines were confirmed to be safe with regard to both non-carcinogenic and carcinogenic risks.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE