Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development and validation of LC-MS/MS method for simultaneous determination of dabigatran etexilate and its active metabolites in human plasma, and its application in a pharmacokinetic study

Authors
Park, In-HwanPark, Jin-WooChung, HyewonKim, Jong-MinLee, SangjinKim, Kyoung-AhPark, Ji-Young
Issue Date
5-Sep-2021
Publisher
ELSEVIER
Keywords
Dabigatran; Dabigatran acylglucuronide; Dabigatran etexilate; LC-MS/MS
Citation
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, v.203
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
Volume
203
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/136385
DOI
10.1016/j.jpba.2021.114220
ISSN
0731-7085
Abstract
Dabigatran is a direct thrombin inhibitor widely used for preventing various thrombotic events. Although there are several established LC-MS/MS based methods for quantification of plasma dabigatran etexilate and its active metabolites (dabigatran and dabigatran acylglucuronide), so far, there are no studies for simultaneous quantification of dabigatran etexilate, dabigatran, and dabigatran acylglucuronide in human plasma samples. In the present study, a novel and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for assessment of dabigatran pharmacokinetics in human plasma samples according to FDA guidelines. We used the new method to simultaneously quantify dabigatran etexilate, dabigatran, and dabigatran acylglucuronide in human plasma samples. After deproteinization using acetonitrile, the supernatants were evaporated, dissolved in a mobile phase, and finally injected onto an HPLC system with a silica-based C-18 reverse-phase column. Mass spectrometer system was operated in multiple reaction monitoring mode (MRM) (dabigatran etexilate: m/z 629.464 -> 290.100; dabigatran: m/z 472.300 -> 289.100, and dabigatran acylglucuronide: m/z 648.382 -> 289.100) and all the components were confirmed using positive electrospray ionization (ESI). Correlation coefficients > 0.999 were achieved for all the calibration curves with linear regression. The intra-day and inter-day accuracies of dabigatran etexilate, dabigatran, and dabigatran acylglucuronide were 95.84-109.44 %, 99.4-103.42 %, and 98.37-104.42 %, respectively, while their corresponding precisions were 3.84-9.79, 1.07-8.76 %, and 2.56-4.51 %, respectively. We successfully applied the new method to determine the pharmacokinetic profiles of dabigatran etexilate, dabigatran, and dabigatran acylglucuronide in humans. Our findings demonstrated the method as robust, reliable, and sensitive. (C) 2021 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Ji Young photo

Park, Ji Young
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE