Unavoidable but minimizable microdefects in a polycrystalline zeolite membrane: its remarkable performance for wet CO2/CH4 separation
- Authors
- Jeong, Yanghwan; Lee, Minseong; Lee, Gihoon; Hong, Sungwon; Jang, Eunhee; Choi, Nakwon; Choi, Jungkyu
- Issue Date
- 7-6월-2021
- Publisher
- ROYAL SOC CHEMISTRY
- Citation
- JOURNAL OF MATERIALS CHEMISTRY A, v.9, no.21, pp.12593 - 12605
- Indexed
- SCIE
SCOPUS
- Journal Title
- JOURNAL OF MATERIALS CHEMISTRY A
- Volume
- 9
- Number
- 21
- Start Page
- 12593
- End Page
- 12605
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/137310
- DOI
- 10.1039/d1ta01286j
- ISSN
- 2050-7488
- Abstract
- We prepared a hydrophobic deca-dodecasil 3 rhombohedral@chabazite (DDR@CHA) zeolite hybrid film comprised mainly of DDR zeolite. Specifically, the pore size of the DDR zeolite (0.36 x 0.44 nm(2)) is ideal for molecular-sieve-based CO2 (0.33 nm) separation from CH4 (0.38 nm), which is critical for upgrading biogas. We demonstrated that an appropriate choice of calcination conditions was the key factor controlling the formation of defects and, consequently, determining the final membrane performance. Simply put, low-temperature calcination in O-3 eliminated defect formation and, thus, achieved a very high performance for dry CO2 permselectivity over CH4 (CO2/CH4 separation factor (SF) of ca. 523 +/- 96 at ca. 50 degrees C, which is a representative temperature of biogas streams). Surprisingly, high separation performances (CO2/CH4 SF of 422) for water-vapor-containing CO2/CH4 mixtures (at 100% humidity and 50 degrees C) required the formation of a few defects, which in turn necessitated optimal calcination at ca. 450 degrees C in O-2. The defect structures were quantitatively analyzed by combining fluorescence confocal optical microscopy with gas-permeation modeling. Furthermore, the inhibition of water-molecule-adsorption on CO2 permeation rates was estimated. This clearly revealed that fully opening the all-silica hydrophobic DDR zeolite micropores, while minimizing the formation of concomitant defects, helped to achieve the highest ever CO2 permselectivities for wet CO2/CH4 mixtures. In contrast, the elimination of defects by calcination in O-3 was the key to achieving a very high dry CO2/CH4 separation performance.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > Department of Chemical and Biological Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.