Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Quantitative visual tests in primary open-angle glaucoma patients according to three different lights with different color-rendering index

Authors
Kim, Sang WooGo, YoungWookKang, Sang-OokLee, Chang Kyu
Issue Date
28-May-2021
Publisher
BMC
Keywords
color rendering index; glaucoma; quantitative visual test; quantum dot LED
Citation
BMC OPHTHALMOLOGY, v.21, no.1
Indexed
SCIE
SCOPUS
Journal Title
BMC OPHTHALMOLOGY
Volume
21
Number
1
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/137366
DOI
10.1186/s12886-021-02005-2
ISSN
1471-2415
Abstract
Purpose To compare quantitative visual tests, such as visual acuity, contrast sensitivity, and color vision tests in patients with primary open-angle glaucoma (POAG) patients according to three different light systems with different color-rendering index (CRI). Methods This was a cross-sectional study of 36 eyes in 36 patients with POAG. Three different light systems consisting of a 3-band fluorescent lamp (CRI 80), a white LED (CRI 75), and a quantum dot LED (CRI > 95) were used. All lights had the same illuminance of 230 lx to exclude illuminance effects. The visual testing included best-corrected visual acuity (BCVA) using an ETDRS chart, a CSV-1000E contrast test, and a color test performed by the Farnsworth Munsell 100-hue test. Results There was no significant difference in BCVA (p = 0.86). There were no significant differences in the detail contrast tests according to the three light systems (p = 0.95, p = 0.94, p = 0.94, respectively, p = 0.64). There was significant difference between the three light systems in color test (p = 0.042). The color test scores with a quantum dot LED were significantly lower than those of the white LED and 3-band fluorescent lamp (p = 0.03 and 0.047, respectively). Conclusions POAG patients did not show significant differences in visual acuity scores and contrast test scores, expressed as black and white symbols, according to the different light systems. However, POAG patients tested under a quantum dot LED (CRI > 95) could distinguish color differences better than in the other light systems.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Advanced Materials Chemistry > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE