Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of Building Energy Performance with Optimal Control of Movable Shading Device Integrated with PV System

Authors
Jung, Dong EunLee, ChanukLee, Kwang HoShin, MinjaeDo, Sung Lok
Issue Date
4월-2021
Publisher
MDPI
Keywords
artificial neural network; movable shading device; optimal control; photovoltaic system; window heat transfer
Citation
ENERGIES, v.14, no.7
Indexed
SCIE
SCOPUS
Journal Title
ENERGIES
Volume
14
Number
7
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/137706
DOI
10.3390/en14071799
ISSN
1996-1073
Abstract
Among the envelope components (e.g., walls, roofs, floors, and windows, etc.) affecting the cooling and heating load of buildings, windows are the most thermally vulnerable. Shading devices can minimize the thermal load on windows due to solar radiation and decrease radiation effects. However, the load changes due to convection and conduction should be considered. Therefore, when a shading device is applied to a window, control logic for thermal blocking and heat retention is necessary to prevent the load changes. In addition, by combining the opposite features of photovoltaic (PV) that require solar radiation and the shading device to block solar radiation, energy-saving and production can be achieved simultaneously. Therefore, this study minimized the thermal effects of windows using a movable shading device integrated with PV and evaluated the PV power generation. This study evaluated the effects on window heat transfer by applying artificial intelligence techniques, which have recently attracted attention, to system operation. To achieve this, artificial neural network (ANN)-based control logic was developed, and the control performance of the system was assessed using simulations. In ANN control, the window heat transfer was 86.3% lower in a cooling period and 9.7% lower in a heating period compared with that of a shading device fixed at 45 degrees. Furthermore, the PV system produced 3.0 to 3.1% more electric power under optimal control during the cooling period.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Architecture > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE