Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of residual bond behavior of CFRP and steel bars embedded in UHPC after exposure to elevated temperatureopen access

Authors
Yoo, Sun-JaeKim, Young-HwiYuan, Tian-FengYoon, Young-Soo
Issue Date
15-9월-2022
Publisher
ELSEVIER
Keywords
Carbon-fiber-reinforced-polymer; Steel rebar; Ultra-high-Performance-concrete; No-slump-high-strength-high-ductility-; concrete; Pull-out test; Elevated temperature
Citation
JOURNAL OF BUILDING ENGINEERING, v.56
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF BUILDING ENGINEERING
Volume
56
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/142863
DOI
10.1016/j.jobe.2022.104768
ISSN
2352-7102
Abstract
Carbon-fiber-reinforced-polymer (CFRP) bar with high tensile strength is expecting when used with ultra-high-strength-concrete (UHPC), but the reduction of mechanical properties of CFRP under thermal effects is an important issue. This study invesitigated the residual bond strength of CFRP bars in UHPC specimens after exposure to elevated temperatures. For comparison, the residual bond strength of steel rebar was also conducted after exposure to elevated temperatures. For this purpose, the pull-out specimens with dimensions of 150 mm x 150 mm x 150 mm were fabricated to investigate the effects of temperature at ambient temperature and after exposure to elevated temperature at 150 degrees C and 250 degrees C. As a result, the CFRP bars embedded in UHPC showed a reduction in the bond stress and these reducing effects is remarkable as the increase of the thermal temperature. Contrary to the test result of the CFRP bars, there was no significant difference in bond strength of the steel rebar in UHPC after exposure to elevated temperature, rather, the residual bond strength after exposure to the elevated temperature at 250 degrees C increased compared to ambient temperature by 9%. In order to quantitatively identify the initial bond slip behavior after exposure to thermal heating, the experimental results were compared with the modified BPE model and the CMR model, and each parameter was compared by the least square methods. The bond-slip model for CMR was more suitable than the modified BPE model in both the CFRP bars and steel bars, and the experimental results were compared with the previous research; the residual bond stress of CFRP bar in UHPC satisfies the criteria presented by ACI 440.6 M after the heating.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Young Soo photo

Yoon, Young Soo
공과대학 (건축사회환경공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE