- Abstract
- The minimization of Pt loadings on Au via facile fabrication methods remains a grand challenge in the devel-opment of commercially viable electrodes for direct formic acid fuel cells. Herein, we report a simple electro-chemical strategy to prepare atomic Pt clusters on Au dendrites supported by carbon paper (CP) as a gas diffusion electrode. At highly negative deposition potentials, Pt deposition is autonomously quenched by immediate adsorption of discharged proton (H) on Pt surface, while highly roughened Au dendrites lead to resis-tance-capacitance delay for the transient cathodic current. As a result, the suppressed Pt nucleation and self -terminated Pt growth allows for the formation of isolated Pt sites on Au dendrites. The Pt/Au/CP with an ultra-low Pt loading of 5.0 mu gPt/cmgeo 2demonstrates high selectivity for direct pathway of formic acid oxidation reaction (FAOR), owing to the ensemble effect. A gradual increase of FAOR activity is observed during cycling test and then, the 20 cycled Pt/Au/CP shows remarkable FAOR activity in half-cell test, exceeding state-of-the-art Pt-Au catalysts. Theoretical calculation indicates that the stabilized intermediate on Pt clusters accelerates the direct FAOR pathway. CO chemisorption analysis reveals that the isolated Pt sites remain stable throughout the reaction. Single cell test for direct formic acid fuel cell with 20 cycled Pt/Au/CP anode demonstrate two-order higher Pt mass activity and mass power density, compared with values reported in recent literature.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > Department of Materials Science and Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.