Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development of modified scintillator-based single-crystal position-sensitive 4 pi Compton camera for a portable radiation imaging device

Authors
Lee, HyounggunPark, JisuLee, Wonho
Issue Date
11-Nov-2022
Publisher
ELSEVIER
Keywords
Position-sensitive; Compton camera; Scintillator; Unmanned aerial vehicle
Citation
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.1043
Indexed
SCIE
SCOPUS
Journal Title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
Volume
1043
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/145454
DOI
10.1016/j.nima.2022.167485
ISSN
0168-9002
Abstract
After the nuclear accident at the Fukushima Daiichi Nuclear Power Plant, researchers focused on the accident and studied the effects of leaked radiation based on radiation detection and measurement. Many methods can be used for monitoring and mapping natural and leaked radionuclides; however, portable detectors installed in unmanned ground or aerial vehicles (UAVs) can measure radioactivity near the target point, preventing damage to the human body from radiation in highly contaminated areas. Compton cameras have a wider field-of-view (FOV) and less weight than a detector system that uses a mechanical collimator. In a previous study, a position-sensitive 4 pi Compton camera based on a lutetium-yttrium oxyorthosilicate (LYSO) scintillator attached to silicon photomultipliers (SiPMs) was developed. Compared with a semiconductor-based Compton camera operating with a power device supplying more than a thousand volts, our system requires a maximum of approximately several tens of volts. In addition, our Compton camera has a single-crystal structure; hence, it has advantages in terms of FOV and efficiency over a Compton camera that utilizes separate detectors. In this study, a modified scintillator-based Compton camera was created using an advanced SiPM model and a gadolinium aluminum gallium garnet (GAGG) scintillator. In the experiment, Ba-133, Na-22, and Cs-137 radionuclides were used for data acquisition, and simple back-projection and list-mode maximum likelihood expectation maximization algorithms were used to reconstruct the Compton images. The 4 pi FOV coverage was evaluated using Compton imaging and angular resolution measure (ARM), and the results indicated that FOV coverage was degraded when the angle between the radiation source and the perpendicular axis of the detector was near 45 degrees. The degradation of the ARM reflected as the bimodal distribution became more severe for the Compton camera based on the LYSO scintillator than that based on the GAGG scintillator, which was attributed to the intrinsic radiation of LYSO from Lu-176 considered as background noise. In the evaluation of intrinsic efficiency, the influence of intrinsic radiation was significantly large. Without background noise rejection, the intrinsic efficiencies for 356, 511, and 662 keV radiation were 0.66%-1.28%, and 1.50%-3.05% for the detection system based on the GAGG and LYSO scintillators, respectively. After background noise rejection, the intrinsic efficiencies were re-calculated as 0.64%-1.27% and 1.39%-1.72% for the detection system based on the GAGG and LYSO scintillator, respectively.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Won ho photo

Lee, Won ho
College of Health Sciences (School of Health and Environmental Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE