Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Cardiac Dysfunction Is Not Associated with Increased Reintubation Rate in Patients Treated with Post-extubation High-Flow Nasal Cannulaopen access

Authors
Sim, J.K.Choi, J.Oh, J.Y.Min, K.H.Hur, G.Y.Lee, S.Y.Shim, J.J.Lee, Y.S.
Issue Date
2022
Publisher
Korean National Tuberculosis Association
Keywords
Cardiac Dysfunction; Extubation; High-Flow Nasal Cannula; Reintubation
Citation
Tuberculosis and Respiratory Diseases, v.85, no.4, pp.332 - 340
Indexed
SCOPUS
KCI
Journal Title
Tuberculosis and Respiratory Diseases
Volume
85
Number
4
Start Page
332
End Page
340
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/146994
DOI
10.4046/trd.2022.0040
ISSN
1738-3536
Abstract
Background: Cardiac dysfunction patients have long been considered at high risk of reintubation. However, it is based on past studies in which only conventional oxygen therapy was applied after extubation. We investigated association between cardiac dysfunction and reintubation rate in situation where high-flow nasal cannula (HFNC) was widely used during post-extubation period. Methods: We conducted a retrospective observational cohort study of patients treated with HFNC after planned extubation in medical intensive care unit of single tertiary center. Patients were divided into normal function group (ejection fraction [EF] ≥45%) and cardiac dysfunction group (EF <45%). The primary outcome was reintubation rate within 72 hours following extubation. Results: Of 270 patients, 35 (13%) had cardiac dysfunction. Baseline characteristics were similar in both groups. There were no differences in the changes in vital signs between the two groups during the first 12 hours after extubation except diastolic blood pressure. The reintubation rates were 20% and 17% for cardiac dysfunction group and normal function group, respectively (p=0.637). In a multivariate Cox regression analysis, cardiac dysfunction was not associated with an increased risk of reintubation within 72 hours following extubation (hazard ratio, 1.56; p=0.292). Conclusion: Cardiac dysfunction was not associated with increased reintubation rate within 72 hours when HFNC is immediately applied after planned extubation. Copyright © 2022 The Korean Academy of Tuberculosis and Respiratory Diseases.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE