Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Simultaneous Multislice Readout-Segmented Echo Planar Imaging for Diffusion-Weighted MRI in Patients With Invasive Breast Cancers

Authors
Song, Sung EunWoo, Ok HeeCho, Kyu RanSeo, Bo KyoungSon, Yo HanGrimm, RobertLiu, WeiMoon, Woo Kyung
Issue Date
4월-2021
Publisher
WILEY
Keywords
magnetic resonance imaging; diffusion& #8208; weighted imaging; simultaneous excitation; breast cancer
Citation
JOURNAL OF MAGNETIC RESONANCE IMAGING, v.53, no.4, pp.1108 - 1115
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF MAGNETIC RESONANCE IMAGING
Volume
53
Number
4
Start Page
1108
End Page
1115
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/49448
DOI
10.1002/jmri.27433
ISSN
1053-1807
Abstract
Background In diffusion-weighted imaging (DWI) of breast MRI, simultaneous multislice acceleration techniques can be used for readout-segmented echo planar imaging (rs-EPI) to shorten the scan time. Purpose To compare the image quality, apparent diffusion coefficient (ADC) value, and scan time of rs-EPI and simultaneous multislice rs-EPI (SMS rs-EPI) sequences. Study Type Retrospective. Subjects In all, 134 consecutive women (mean age: 55.3 years) with invasive breast cancer who underwent preoperative MRI. Field Strength/ Sequences 3.0T; rs-EPI sequence, prototypic SMS rs-EPI sequence and dynamic contrast-enhanced MRI (DCE-MRI) sequence Assessment For quantitative comparison, two radiologists independently measured the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), lesion contrast, and apparent diffusion coefficient (ADC). For qualitative comparison, image quality, lesion conspicuity, and reader preference were assessed with a reference of DCE-MRI. Statistical Tests Paired t-tests and Mann-Whitney tests were used. Results For SNR and CNR, there were no differences between the sequences (P = 0.342 and 0.665 for reader 1; P = 0.606 and P = 0.116 for reader 2). Lesion contrast of SMS rs-EPI was higher than that of rs-EPI (P < 0.05 for both reader 1 and reader 2). Mean tumor ADC was similar in rs-EPI and SMS rs-EPI sequences (0.98 +/- 0.22 vs. 1.00 +/- 0.22; P = 0.291 for reader 1, 0.98 +/- 0.21 vs. 1.00 +/- 0.22; P = 0.418 for reader 2). Regarding qualitative comparison, image quality and lesion conspicuity were higher in SMS rs-EPI than in rs-EPI (both P < 0.05 for both readers). The two readers regarded SMS rs-EPI as superior or equal to rs-EPI in over 90% of cases. The acquisition time was 4:30 minutes for rs-EPI and 2:31 minutes for SMS rs-EPI. Data Conclusion The SMS rs-EPI sequence resulted in a similar ADC value and better image quality than the rs-EPI sequence in a 44.1% reduced scan time. Level of Evidence 4 Technical Efficacy 3
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE