Slime-meter for assessment of slime thickness based on electrical properties in borehole
- Authors
- Hong, Won-Taek; Woo, Gyuseong; Park, Min-Chul; Lee, Jong-Sub
- Issue Date
- 11월-2020
- Publisher
- ELSEVIER
- Keywords
- Borehole; Drilled shaft; Electrical resistivity; Slime; Stabilizing liquid
- Citation
- AUTOMATION IN CONSTRUCTION, v.119
- Indexed
- SCIE
SCOPUS
- Journal Title
- AUTOMATION IN CONSTRUCTION
- Volume
- 119
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/52001
- DOI
- 10.1016/j.autcon.2020.103328
- ISSN
- 0926-5805
- Abstract
- The slime formed in the borehole causes the excessive displacement and loss of the bearing capacity of the drilled shafts. Thus, an accurate evaluation of the slime thickness is required during the construction of drilled shafts. In this study, a slime-meter was developed for the effective assessment of slime thickness based on electrical re-sistivity. As the application tests, the slime thicknesses in the boreholes were evaluated before and after slime removal and according to the testing positions, and the experimental results show that the electrical resistivity clearly detects slime and the reduction of slime thickness. Therefore, the slime-meter developed in this study can be effectively used for the assessment of slime thickness and ensure the bearing capacity of the drilled shafts. In addition, the slime-meter may also be applicable for the evaluation of borehole conditions such as sand content in stabilizing liquid and the slime density using the characteristics of the electrical resistivity.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.